Sound Transmission by Boilers and Chimneys
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F03%3A02089217" target="_blank" >RIV/68407700:21220/03:02089217 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Sound Transmission by Boilers and Chimneys
Popis výsledku v původním jazyce
During last years several problematic projects of boiler houses gave grievance for the sake of an excessive noise in outside of them. Experience from realized sound measurements on many boilers show, that noise generated in outside by the chimney is verydepending not only on noise of a burner but mainly on a transmission loss or an amplification of boiler incl. smoke-flu and chimney too. In the paper are presented some findings which were obtained by theoretical and experimental works on a array of boiler houses. It was demonstrated, that own frequencies of particular pipes and cavities inside of boiler must not be the same as own frequencies of e smoke-flu and a chimney. In case,it is all acoustic system in tune, the chimney radiates more acoustic energy on own frequencies as a big organ. Boiler and burner design would be respect a condition, that any part of boiler pipes a cavities in the first case must not to have the same own frequencies. The theoretic formulae for a calculation
Název v anglickém jazyce
Sound Transmission by Boilers and Chimneys
Popis výsledku anglicky
During last years several problematic projects of boiler houses gave grievance for the sake of an excessive noise in outside of them. Experience from realized sound measurements on many boilers show, that noise generated in outside by the chimney is verydepending not only on noise of a burner but mainly on a transmission loss or an amplification of boiler incl. smoke-flu and chimney too. In the paper are presented some findings which were obtained by theoretical and experimental works on a array of boiler houses. It was demonstrated, that own frequencies of particular pipes and cavities inside of boiler must not be the same as own frequencies of e smoke-flu and a chimney. In case,it is all acoustic system in tune, the chimney radiates more acoustic energy on own frequencies as a big organ. Boiler and burner design would be respect a condition, that any part of boiler pipes a cavities in the first case must not to have the same own frequencies. The theoretic formulae for a calculation
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2003
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the Tenth International Congress on Sound and Vibration
ISBN
—
ISSN
—
e-ISSN
—
Počet stran výsledku
1
Strana od-do
104-104
Název nakladatele
International Institute of Acoustics and Vibration
Místo vydání
Auburn
Místo konání akce
Stockholm
Datum konání akce
7. 6. 2003
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—