Assessment of Carburizing Potential of Furnace Atmosphere by Lambda Probe
Popis výsledku v původním jazyce
Several measuring of voltage of the oxygen probe and the lambda probe were done. Lambda probe was measured with various longitude of supply pipeline. Further was measured the temperature of warming sensor of the lambda probe and the chemical compositionof the ZrO2 ceramics. During the measuring was temperature in furnace 830 oC. The temperature of sensor of lambda probe was 670 oC. Optimum temperature for the function of the lambda probe is about 600 oC. Higher temperature is better for ionic conductivity of ZrO2 ceramics. Because the temperature of oxygen probe is the same with the temperature in furnace (830 oC) and the temperature of lambda probe is lower (670 oC), it is impossible to give reasons for higher voltage on lambda probe. At lower temperature of sensor of lambda probe the voltage in output should be lower than on the oxygen probe, which isn´t.
Název v anglickém jazyce
Assessment of Carburizing Potential of Furnace Atmosphere by Lambda Probe
Popis výsledku anglicky
Several measuring of voltage of the oxygen probe and the lambda probe were done. Lambda probe was measured with various longitude of supply pipeline. Further was measured the temperature of warming sensor of the lambda probe and the chemical compositionof the ZrO2 ceramics. During the measuring was temperature in furnace 830 oC. The temperature of sensor of lambda probe was 670 oC. Optimum temperature for the function of the lambda probe is about 600 oC. Higher temperature is better for ionic conductivity of ZrO2 ceramics. Because the temperature of oxygen probe is the same with the temperature in furnace (830 oC) and the temperature of lambda probe is lower (670 oC), it is impossible to give reasons for higher voltage on lambda probe. At lower temperature of sensor of lambda probe the voltage in output should be lower than on the oxygen probe, which isn´t.
Klasifikace
Druh
A - Audiovizuální tvorba
CEP obor
JG - Hutnictví, kovové materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2003
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
ISBN
80-01-02708-2
Místo vydání
Praha
Název nakladatele resp. objednatele
—
Verze
—
Identifikační číslo nosiče
neuvedeno