Using a Phonocardiography In a Pulse Wave Velocity Measurement
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F03%3A03094319" target="_blank" >RIV/68407700:21220/03:03094319 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Using a Phonocardiography In a Pulse Wave Velocity Measurement
Popis výsledku v původním jazyce
A data acquisition is realised using purely non-invasive measuring mode, i.e. phonocardiography, in this project. A blood pulse wave velocity (PWV) in human arterial tree is determined by analyse phonocardiographic (PCG) records. Two signals are needed at minimum for an estimation of the pulse wave velocity. All of these signals have to be measured simultaneously from different points on a human body using electronic phonendoscopes. Pressure and sound manifestations of the pulse wave spreading are recorded in a cardiovascular system by this measuring device. Recorded signals are transferred to the computer in a real time mode, where they are saved for a next data processing (filtering, standardisation, and analysis). The pulse wave velocity is estimated using a cross-correlation analysis of recorded phonocardiographic signals.
Název v anglickém jazyce
Using a Phonocardiography In a Pulse Wave Velocity Measurement
Popis výsledku anglicky
A data acquisition is realised using purely non-invasive measuring mode, i.e. phonocardiography, in this project. A blood pulse wave velocity (PWV) in human arterial tree is determined by analyse phonocardiographic (PCG) records. Two signals are needed at minimum for an estimation of the pulse wave velocity. All of these signals have to be measured simultaneously from different points on a human body using electronic phonendoscopes. Pressure and sound manifestations of the pulse wave spreading are recorded in a cardiovascular system by this measuring device. Recorded signals are transferred to the computer in a real time mode, where they are saved for a next data processing (filtering, standardisation, and analysis). The pulse wave velocity is estimated using a cross-correlation analysis of recorded phonocardiographic signals.
Klasifikace
Druh
A - Audiovizuální tvorba
CEP obor
FS - Lékařská zařízení, přístroje a vybavení
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2003
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
ISBN
0-7803-8293-5
Místo vydání
Darmstadt
Název nakladatele resp. objednatele
Not available
Verze
—
Identifikační číslo nosiče
IEEE Cat.Number 03EX795C