Není k dispozici
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F04%3A02100372" target="_blank" >RIV/68407700:21220/04:02100372 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
kLa Measurement by Dynamic Sulfite Method in Agitated Vessel
Popis výsledku v původním jazyce
The important characteristic of gas-liquid contactors is the intensity of mass transfer which is characterized by the volumetric mass transfer coefficient - kLa. For the kLa measurement various methods exist (i.e. steady state methods, dynamic pressure method, gassing-out method, dynamic start-up method). One of these methods is dynamic sulfite method. The method is based on simultaneous monitoring of dissolved oxygen and sulfite ions concentrations after an injection of sulfite solution (or other oxygen consuming species) to the batch initially saturated with aerating gas. The concentration of the sulfite oxidized in an analyzed sample of liquid determines the initial oxygen concentration corrected to non-ideal mixing. The volumetric mass transfer coefficient kLa is given by the ratio of the oxygen and sulfite concentration at any known time.
Název v anglickém jazyce
kLa Measurement by Dynamic Sulfite Method in Agitated Vessel
Popis výsledku anglicky
The important characteristic of gas-liquid contactors is the intensity of mass transfer which is characterized by the volumetric mass transfer coefficient - kLa. For the kLa measurement various methods exist (i.e. steady state methods, dynamic pressure method, gassing-out method, dynamic start-up method). One of these methods is dynamic sulfite method. The method is based on simultaneous monitoring of dissolved oxygen and sulfite ions concentrations after an injection of sulfite solution (or other oxygen consuming species) to the batch initially saturated with aerating gas. The concentration of the sulfite oxidized in an analyzed sample of liquid determines the initial oxygen concentration corrected to non-ideal mixing. The volumetric mass transfer coefficient kLa is given by the ratio of the oxygen and sulfite concentration at any known time.
Klasifikace
Druh
A - Audiovizuální tvorba
CEP obor
CI - Průmyslová chemie a chemické inženýrství
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
ISBN
80-86059-40-5
Místo vydání
Praha
Název nakladatele resp. objednatele
—
Verze
—
Identifikační číslo nosiče