Analýza MKP modelu nového typu totální náhrady meziobratlového disku
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F04%3A02101420" target="_blank" >RIV/68407700:21220/04:02101420 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Analysis of FEM Model a New Type of Intervertebral Disc Replacement
Popis výsledku v původním jazyce
Most adults will su_er low back pain at some time in their lives. Some of them has to undergo spinal surgery procedure. The major causes of back pain are degenerative disc and spinal diseases or injuries. Currently the most common spinal surgery procedure in treatment of low back pain is spinal fusion. In this procedure one or more of the vertebrae of the spine are joined together. Fusion surgery eliminates the movement between the fused vertebrae, which leads to increased load and stress on the adjacent vertebrae. Major disadvantage of this fusion is decrease of mobility in dependence on the increasing of adjacent vertebras and discs load.This causes next degenerative changes followed by another pain. None of current available artificial intervertebral discs, does not respect all physiological properties of natural disc. The main disadvantage of current available artificial discs is low ability for damping and unlimited rotational movement by axial rotation.Therefore surgeons
Název v anglickém jazyce
Analysis of FEM Model a New Type of Intervertebral Disc Replacement
Popis výsledku anglicky
Most adults will su_er low back pain at some time in their lives. Some of them has to undergo spinal surgery procedure. The major causes of back pain are degenerative disc and spinal diseases or injuries. Currently the most common spinal surgery procedure in treatment of low back pain is spinal fusion. In this procedure one or more of the vertebrae of the spine are joined together. Fusion surgery eliminates the movement between the fused vertebrae, which leads to increased load and stress on the adjacent vertebrae. Major disadvantage of this fusion is decrease of mobility in dependence on the increasing of adjacent vertebras and discs load.This causes next degenerative changes followed by another pain. None of current available artificial intervertebral discs, does not respect all physiological properties of natural disc. The main disadvantage of current available artificial discs is low ability for damping and unlimited rotational movement by axial rotation.Therefore surgeons
Klasifikace
Druh
A - Audiovizuální tvorba
CEP obor
BO - Biofyzika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
ISBN
80-01-02958-1
Místo vydání
Praha
Název nakladatele resp. objednatele
—
Verze
—
Identifikační číslo nosiče
neuvedeno