Distribuce oxidu uhličitého produkovaného lidmi v místnosti: Část 2 - Měření v budovách
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F04%3A02114621" target="_blank" >RIV/68407700:21220/04:02114621 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Distribution of Carbon Dioxide Produced by People in a Room: Part 2 - Field Study
Popis výsledku v původním jazyce
Carbon dioxide exhaled by people can be used as a tracer gas for air change measurements in homes. Good mixing of tracer gas with room air is a necessary condition to obtain accurate results. However, the use of fans in dwellings to ensure mixing is inconvenient. The natural room distribution of metabolic CO2 was simulated in laboratory experiments and verified in a field study. The results of the field measurements presented in this paper support the findings of the laboratory study, i.e. that CO2 is well mixed into the room air even though fans were not used. However, spatial variation of the concentration was detected in both studies when constant CO2 emission was obtained. Several critical points of insufficient mixing were identified. If such locations are avoided, additional mixing may not be necessary when using CO2 as a tracer gas in decay and constant emission methods.
Název v anglickém jazyce
Distribution of Carbon Dioxide Produced by People in a Room: Part 2 - Field Study
Popis výsledku anglicky
Carbon dioxide exhaled by people can be used as a tracer gas for air change measurements in homes. Good mixing of tracer gas with room air is a necessary condition to obtain accurate results. However, the use of fans in dwellings to ensure mixing is inconvenient. The natural room distribution of metabolic CO2 was simulated in laboratory experiments and verified in a field study. The results of the field measurements presented in this paper support the findings of the laboratory study, i.e. that CO2 is well mixed into the room air even though fans were not used. However, spatial variation of the concentration was detected in both studies when constant CO2 emission was obtained. Several critical points of insufficient mixing were identified. If such locations are avoided, additional mixing may not be necessary when using CO2 as a tracer gas in decay and constant emission methods.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
DI - Znečištění a kontrola vzduchu
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Book of Abstracts 9th International Conference on Air Distribution in Room
ISBN
—
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
356-357
Název nakladatele
ADAI
Místo vydání
Coimbra
Místo konání akce
Coimbra
Datum konání akce
5. 9. 2004
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—