Testování prvku simulujícího odpor krevního řečiště člověka
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F05%3A02113301" target="_blank" >RIV/68407700:21220/05:02113301 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Testing of Elements Simulating System Resistance of the Human
Popis výsledku v původním jazyce
One of the basic elements of the experimental line simulating cardiovascular system is a model of peripheral resistance. In the Laboratory of Human Biomechanics, two models of bloodstream peripheral resistance are beány developed. These models will be used in the experimental line for aortic pulse wave velocity evaluation. This invasive and non-invasive evaluation will be used for detection of blood vessel wall material properties. The total resistance of the first type of the element could be controlled by a number of resistance segments in use. The second type esistance is constant. Both elements consist of numerous flow splits and a chamber filled with the resistance segments. With all resistance segments active, the total flow cross section increases five times. Both elements proved to be applicable in haemodynamic measurements. The research is conducted in cooperation with the 1st and 3rd Faculty of Medicine of the Charles University in Prague.
Název v anglickém jazyce
Testing of Elements Simulating System Resistance of the Human
Popis výsledku anglicky
One of the basic elements of the experimental line simulating cardiovascular system is a model of peripheral resistance. In the Laboratory of Human Biomechanics, two models of bloodstream peripheral resistance are beány developed. These models will be used in the experimental line for aortic pulse wave velocity evaluation. This invasive and non-invasive evaluation will be used for detection of blood vessel wall material properties. The total resistance of the first type of the element could be controlled by a number of resistance segments in use. The second type esistance is constant. Both elements consist of numerous flow splits and a chamber filled with the resistance segments. With all resistance segments active, the total flow cross section increases five times. Both elements proved to be applicable in haemodynamic measurements. The research is conducted in cooperation with the 1st and 3rd Faculty of Medicine of the Charles University in Prague.
Klasifikace
Druh
A - Audiovizuální tvorba
CEP obor
BO - Biofyzika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA106%2F04%2F1181" target="_blank" >GA106/04/1181: Identifikace materiálových vlastností cévních stěn</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
ISBN
1-86854-624-1
Místo vydání
Cairo
Název nakladatele resp. objednatele
—
Verze
—
Identifikační číslo nosiče
neuvedeno