Experience with Moisture Sorption Control Implementation in Historical Archives
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F06%3A00121127" target="_blank" >RIV/68407700:21220/06:00121127 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Experience with Moisture Sorption Control Implementation in Historical Archives
Popis výsledku v původním jazyce
The paper deals with a novel approach to inhibiting the harmful impact of moisture sorption in old art works or historical exhibits preserved in remote historical buildings. Historical interiors reused as deposit or exhibition rooms for collections of cultural heritage and not provided with heating are the main concern in this paper. The proposed microclimate adjustment consists in leaving the interior temperature to run almost its spontaneous yearly cycle while the air humidity is maintained in a specific relationship to the current interior temperature.The interior air humidity is modestly adjusted to prevent historical exhibits or art works from harmful variations in the content of absorbed moisture, which would otherwise arise owing to the interiortemperature drifts. Since a direct measurement of moisture content is not feasible the air humidity is controlled via a model-based principle.
Název v anglickém jazyce
Experience with Moisture Sorption Control Implementation in Historical Archives
Popis výsledku anglicky
The paper deals with a novel approach to inhibiting the harmful impact of moisture sorption in old art works or historical exhibits preserved in remote historical buildings. Historical interiors reused as deposit or exhibition rooms for collections of cultural heritage and not provided with heating are the main concern in this paper. The proposed microclimate adjustment consists in leaving the interior temperature to run almost its spontaneous yearly cycle while the air humidity is maintained in a specific relationship to the current interior temperature.The interior air humidity is modestly adjusted to prevent historical exhibits or art works from harmful variations in the content of absorbed moisture, which would otherwise arise owing to the interiortemperature drifts. Since a direct measurement of moisture content is not feasible the air humidity is controlled via a model-based principle.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/1M0567" target="_blank" >1M0567: Centrum aplikované kybernetiky</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Advanced Engineering Design AED 2006
ISBN
80-86059-44-8
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
—
Název nakladatele
ČVUT
Místo vydání
Praha
Místo konání akce
Prague
Datum konání akce
11. 6. 2006
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—