Intenzifikace pulzní regenerace průmyslových filtrů
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F06%3A02119354" target="_blank" >RIV/68407700:21220/06:02119354 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Intensification of Pulse-Jet Cleaning of Industrial Filters
Popis výsledku v původním jazyce
The paper deals with the influence of free volume rate of the outlet and inlet part of the filter. An experimental filter unit with a single filter bag was used for measurement. For evaluation of the tested alternatives a point evaluation system was used. It comprises 6 evaluation factors, which follow from the measured pressure time dependence. First experiments showed that volumes of the inlet and outlet filter parts have a significant influence on the pulse-jet cleaning efficiency. For a more detailed research the experimental filter was reconstructed. 16 alternatives of the filter arrangement were tested. The best was the alternative with the largest volumes on both sides of the filter. The size of the outlet as well as the inlet volume has a positive influence on the point evaluation of the alternative. This conclusion has a considerable influence on the pulse-jet cleaning efficiency and thus on the pressurized air consumption, the filter pressure loss and operational costs.
Název v anglickém jazyce
Intensification of Pulse-Jet Cleaning of Industrial Filters
Popis výsledku anglicky
The paper deals with the influence of free volume rate of the outlet and inlet part of the filter. An experimental filter unit with a single filter bag was used for measurement. For evaluation of the tested alternatives a point evaluation system was used. It comprises 6 evaluation factors, which follow from the measured pressure time dependence. First experiments showed that volumes of the inlet and outlet filter parts have a significant influence on the pulse-jet cleaning efficiency. For a more detailed research the experimental filter was reconstructed. 16 alternatives of the filter arrangement were tested. The best was the alternative with the largest volumes on both sides of the filter. The size of the outlet as well as the inlet volume has a positive influence on the point evaluation of the alternative. This conclusion has a considerable influence on the pulse-jet cleaning efficiency and thus on the pressurized air consumption, the filter pressure loss and operational costs.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
DI - Znečištění a kontrola vzduchu
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Chemical Industry and Environment V
ISBN
3900 554 57 9
ISSN
—
e-ISSN
—
Počet stran výsledku
9
Strana od-do
504-512
Název nakladatele
Institute of Chemical Engineering Vienna University of Technology
Místo vydání
Vídeň
Místo konání akce
Vídeň
Datum konání akce
2. 5. 2006
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—