Rychlost pulzní vlny v elastické trubici
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F06%3A02123437" target="_blank" >RIV/68407700:21220/06:02123437 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Pulse wave velocity in elastic tube
Popis výsledku v původním jazyce
The velocity of the pulse wave in blood vessels is one of the important hemodynamical parameters to detect health condition or a degree of damage of a diseased artery. To understand the problem, the physiological values must be known. In our laboratory,the velocity of pulse wave in elastic tubes and arteries is measured in vitro by non-invasive method. The method is based on optical measurements of displacement of the pulsating tube wall. A crash test camera with high frame rate of 1000 Hz (fps) was used. The frame rate of 1000 Hz proved to be sufficient to register the high velocities of the pulse wave. The obtained data were evaluated by several methods and compared. The measured pulse wave velocities ranged from 4.5 to 6 m/s, thus in the same orderof magnitude as values based on theoretical calculations and physiological values published in literature. However, for more precise data analysis, more experimental data (longer optical record) is recommended.
Název v anglickém jazyce
Pulse wave velocity in elastic tube
Popis výsledku anglicky
The velocity of the pulse wave in blood vessels is one of the important hemodynamical parameters to detect health condition or a degree of damage of a diseased artery. To understand the problem, the physiological values must be known. In our laboratory,the velocity of pulse wave in elastic tubes and arteries is measured in vitro by non-invasive method. The method is based on optical measurements of displacement of the pulsating tube wall. A crash test camera with high frame rate of 1000 Hz (fps) was used. The frame rate of 1000 Hz proved to be sufficient to register the high velocities of the pulse wave. The obtained data were evaluated by several methods and compared. The measured pulse wave velocities ranged from 4.5 to 6 m/s, thus in the same orderof magnitude as values based on theoretical calculations and physiological values published in literature. However, for more precise data analysis, more experimental data (longer optical record) is recommended.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BO - Biofyzika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA106%2F04%2F1181" target="_blank" >GA106/04/1181: Identifikace materiálových vlastností cévních stěn</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Modelling, Identification, and Control 2006
ISSN
1025-8973
e-ISSN
—
Svazek periodika
25
Číslo periodika v rámci svazku
25
Stát vydavatele periodika
ES - Španělské království
Počet stran výsledku
5
Strana od-do
484-488
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—