A magnetic field effect on a human being has been monitored at the exposure of a part body by a strong pulse magnetic field. A pulse magnetic field, generated by a pseudo-random current, has been used for experimental exposures. A couple of Helmholz coils have been chosen as an applicator. The high-level of the flux density of used magnetic field was c. 60 mT. The influence of the magnetic field has been monitored by evaluations of the bio-impedance changes and by the blood pressure. The bio-impedance has been measured by use of RF signal with the frequency 75 kHz by four-point method on the forearm. The bio-impedance change is a measure of a vasodilatation effect during the cardiac cycle and affection of those effects by a magnetic field too. The blood pressure has been measured in brachial artery by using common semi-automatic cuff pressure gauge
Název v anglickém jazyce
Influence of Magnetic Field on Human
Popis výsledku anglicky
A magnetic field effect on a human being has been monitored at the exposure of a part body by a strong pulse magnetic field. A pulse magnetic field, generated by a pseudo-random current, has been used for experimental exposures. A couple of Helmholz coils have been chosen as an applicator. The high-level of the flux density of used magnetic field was c. 60 mT. The influence of the magnetic field has been monitored by evaluations of the bio-impedance changes and by the blood pressure. The bio-impedance has been measured by use of RF signal with the frequency 75 kHz by four-point method on the forearm. The bio-impedance change is a measure of a vasodilatation effect during the cardiac cycle and affection of those effects by a magnetic field too. The blood pressure has been measured in brachial artery by using common semi-automatic cuff pressure gauge
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceeding ISHF
ISBN
978-972-735-145-9
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
313-318
Název nakladatele
Faculdade de Motricidade Humana
Místo vydání
Lisbon
Místo konání akce
Lisbon
Datum konání akce
14. 6. 2007
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—