Svalové síly stanovené pomocí různých matematických modelů svalu
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F07%3A02134368" target="_blank" >RIV/68407700:21220/07:02134368 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Musculotendon Forces Derived by Different Muscle Models
Popis výsledku v původním jazyce
This study, investigated the accuracy, practicality, and sensitivity of several different methods of calculating muscle forces during functional activities in humans. The upper extremity dynamic system was chosen, where the movement flexion / extension elbow joint was studied. The redundant mechanisms were solved using optimization criteria with and without models of individual muscles according to their active and passive properties. Comparisons with known movements solved by inverse dynamics approachand optimization techniques, provided similar results across to all optimization criteria. Moreover, if muscle models with active and passive properties are included in these analyses, it is relatively easy to calculate muscle forces of both agonists andantagonists. These approaches may be used to provide input data for dynamic FEM stress analysis of bones and bone-implant systems.
Název v anglickém jazyce
Musculotendon Forces Derived by Different Muscle Models
Popis výsledku anglicky
This study, investigated the accuracy, practicality, and sensitivity of several different methods of calculating muscle forces during functional activities in humans. The upper extremity dynamic system was chosen, where the movement flexion / extension elbow joint was studied. The redundant mechanisms were solved using optimization criteria with and without models of individual muscles according to their active and passive properties. Comparisons with known movements solved by inverse dynamics approachand optimization techniques, provided similar results across to all optimization criteria. Moreover, if muscle models with active and passive properties are included in these analyses, it is relatively easy to calculate muscle forces of both agonists andantagonists. These approaches may be used to provide input data for dynamic FEM stress analysis of bones and bone-implant systems.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
ED - Fyziologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta of Bioengineering and Biomechanics
ISSN
1509-409X
e-ISSN
—
Svazek periodika
9
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
PL - Polská republika
Počet stran výsledku
7
Strana od-do
41-47
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—