Úvodní měření pohyblivosti a tuhosti bederní páteře
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F07%3A02137807" target="_blank" >RIV/68407700:21220/07:02137807 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Preliminary measurements of lumbar spine kinematics and stiffness
Popis výsledku v původním jazyce
The purpose of the presented study was the experimental measurement of lumbar spine stiffness and its range of motion. The dependence of torsion moment of lumbar spine segment on deflection of flexion, extension and torsion was observed during experiments. Stiffness of spine segment was determined from measured data. Human lumbar spine was used. All muscles were removed, however all ligaments were preserved. Experiments were carried out on the test system MTS 858.2 MiniBionix, where loading by axial force and torsion moment is possible at the same time. Special Modular Bionix Spine Test Fixator, attached to the test system was used for the measurements. Loading was controlled kinematically (gradual turning) by keeping the axial force equal zero. The results of these experiments are going to be used as input data for creating a model of artificial lumbar spine and new type of artificial disc replacement.
Název v anglickém jazyce
Preliminary measurements of lumbar spine kinematics and stiffness
Popis výsledku anglicky
The purpose of the presented study was the experimental measurement of lumbar spine stiffness and its range of motion. The dependence of torsion moment of lumbar spine segment on deflection of flexion, extension and torsion was observed during experiments. Stiffness of spine segment was determined from measured data. Human lumbar spine was used. All muscles were removed, however all ligaments were preserved. Experiments were carried out on the test system MTS 858.2 MiniBionix, where loading by axial force and torsion moment is possible at the same time. Special Modular Bionix Spine Test Fixator, attached to the test system was used for the measurements. Loading was controlled kinematically (gradual turning) by keeping the axial force equal zero. The results of these experiments are going to be used as input data for creating a model of artificial lumbar spine and new type of artificial disc replacement.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BO - Biofyzika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA106%2F05%2F2174" target="_blank" >GA106/05/2174: Výzkum biokompatibilních materiálů vhodných pro výrobu nového typu spinální náhrady</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the Fifth Australasian Congress on Applied Mechanics
ISBN
0-85825-862-5
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
770-771
Název nakladatele
Engineers Australia
Místo vydání
Brisbane
Místo konání akce
Brisbane
Datum konání akce
10. 12. 2007
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—