Study on lead-bismuth droplets' generation and their removal by an electrostatic precipitator
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F08%3A00155530" target="_blank" >RIV/68407700:21220/08:00155530 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Study on lead-bismuth droplets' generation and their removal by an electrostatic precipitator
Popis výsledku v původním jazyce
The applicability of the electrostatic precipitator for the removal of lead-bismuth droplets generated in the direct-contact boiling lead-bismuth cooled fast reactor is investigated. A small apparatus in which argon gas bubbles through the pool of lead-bismuth and an electrode mounted in the test section is used. The ESP operating voltage was 1000 V. It was found that the removal efficiency of the electrostatic precipitator increases with time up to 96.5%. It appears that the probability of droplet removal is almost independent of the droplet size. There is a small increase in this probability for larger droplets, which is caused likely by the fact that the larger droplets travel at lower velocities. Otherwise the effect of velocity on the removal efficiency is negligible.
Název v anglickém jazyce
Study on lead-bismuth droplets' generation and their removal by an electrostatic precipitator
Popis výsledku anglicky
The applicability of the electrostatic precipitator for the removal of lead-bismuth droplets generated in the direct-contact boiling lead-bismuth cooled fast reactor is investigated. A small apparatus in which argon gas bubbles through the pool of lead-bismuth and an electrode mounted in the test section is used. The ESP operating voltage was 1000 V. It was found that the removal efficiency of the electrostatic precipitator increases with time up to 96.5%. It appears that the probability of droplet removal is almost independent of the droplet size. There is a small increase in this probability for larger droplets, which is caused likely by the fact that the larger droplets travel at lower velocities. Otherwise the effect of velocity on the removal efficiency is negligible.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JF - Jaderná energetika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Progress in Nuclear Energy
ISSN
0149-1970
e-ISSN
—
Svazek periodika
50
Číslo periodika v rámci svazku
2-6
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
5
Strana od-do
—
Kód UT WoS článku
000254598500088
EID výsledku v databázi Scopus
—