Funkce hustoty deformační energie pro cévní stěny založená na limitní průtažnosti vláken
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F08%3A02148096" target="_blank" >RIV/68407700:21220/08:02148096 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Strain energy function for arterial walls based on limiting fiber extensibility
Popis výsledku v původním jazyce
An anisotropic strain energy density function based on limiting fiber extensibility assumption was suggested. The function was deduced directly from isotropic Gent model. A material was modeled as a composite reinforced with two families of helical fibers. The anisotropy of the strain energy function was incorporated via pseudo-invariants I4 and I6. Mathematical expression includes three material parameters. Suitability of the model for a description of arterial mechanical response was verified by regression analysis of experimental data. Computational model based on a cylindrical thick- walled tube with residual strains was used to estimate material parameters. Identified material model fits pressure-radius data of an aortic inflation test successfully. Further upgrades of the model are discussed.
Název v anglickém jazyce
Strain energy function for arterial walls based on limiting fiber extensibility
Popis výsledku anglicky
An anisotropic strain energy density function based on limiting fiber extensibility assumption was suggested. The function was deduced directly from isotropic Gent model. A material was modeled as a composite reinforced with two families of helical fibers. The anisotropy of the strain energy function was incorporated via pseudo-invariants I4 and I6. Mathematical expression includes three material parameters. Suitability of the model for a description of arterial mechanical response was verified by regression analysis of experimental data. Computational model based on a cylindrical thick- walled tube with residual strains was used to estimate material parameters. Identified material model fits pressure-radius data of an aortic inflation test successfully. Further upgrades of the model are discussed.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BJ - Termodynamika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA106%2F08%2F0557" target="_blank" >GA106/08/0557: Materiálové vlastnosti žil a jejich remodelace</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IFMBE Proceedings
ISBN
978-3-540-89207-6
ISSN
1680-0737
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
Springer
Místo vydání
Berlin
Místo konání akce
Antwerp
Datum konání akce
23. 11. 2008
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—