Flux Schemes Based Finite Volume Method for Internal Transonic Flow with Condensation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F11%3A00181508" target="_blank" >RIV/68407700:21220/11:00181508 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61388998:_____/11:00438673
Výsledek na webu
<a href="http://dx.doi.org/10.1002/fld.2223" target="_blank" >http://dx.doi.org/10.1002/fld.2223</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/fld.2223" target="_blank" >10.1002/fld.2223</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Flux Schemes Based Finite Volume Method for Internal Transonic Flow with Condensation
Popis výsledku v původním jazyce
This paper describes the development of numerical method for the solution of condensing steam flow in internal aerodynamics problems. The numerical method is based on the fractional step method, where the resulting set of ODEs is solved by the two-stageRunge-Kutta method and the homogeneous set of PDEs by a finite volume method. The flow does not contain both phases (gas and liquid) in the whole domain, therefore we discuss properties of used finite volume methods in several cases of single-phase transonic flow in a channel and a turbine cascade. We present numerical results of two-phase flow of condensing steam in 2D nozzle achieved by several numerical methods and show the differences in results caused by numerical diffusion.
Název v anglickém jazyce
Flux Schemes Based Finite Volume Method for Internal Transonic Flow with Condensation
Popis výsledku anglicky
This paper describes the development of numerical method for the solution of condensing steam flow in internal aerodynamics problems. The numerical method is based on the fractional step method, where the resulting set of ODEs is solved by the two-stageRunge-Kutta method and the homogeneous set of PDEs by a finite volume method. The flow does not contain both phases (gas and liquid) in the whole domain, therefore we discuss properties of used finite volume methods in several cases of single-phase transonic flow in a channel and a turbine cascade. We present numerical results of two-phase flow of condensing steam in 2D nozzle achieved by several numerical methods and show the differences in results caused by numerical diffusion.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BK - Mechanika tekutin
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA201%2F08%2F0012" target="_blank" >GA201/08/0012: Kvalitativní analýza a numerické řešení problémů proudění</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal for Numerical Methods in Fluids
ISSN
0271-2091
e-ISSN
—
Svazek periodika
65
Číslo periodika v rámci svazku
8
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
16
Strana od-do
953-968
Kód UT WoS článku
000287156600003
EID výsledku v databázi Scopus
—