Stress distribution within basal dental implants and on the interface to the bone. Influence of the design of the bridgework in the atrophied posterior mandible: the concept of supporting polygon.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F11%3A00182817" target="_blank" >RIV/68407700:21220/11:00182817 - isvavai.cz</a>
Výsledek na webu
<a href="http://issuu.com/implant/docs/id_vol6_nr3_2011_engl_journal" target="_blank" >http://issuu.com/implant/docs/id_vol6_nr3_2011_engl_journal</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Stress distribution within basal dental implants and on the interface to the bone. Influence of the design of the bridgework in the atrophied posterior mandible: the concept of supporting polygon.
Popis výsledku v původním jazyce
This study analyses the force transfer and stress distribution of an implant supported circular bridge with rectangular crossection 3x3.5mm bridge in the atrophied mandible and considers two different designs for the bridge in the posterior mandible. Asa result we can conclude that the direct (straight) connection between the posterior implant in the mandible and the bridge is from the biomechanic point of view the least desireable solution for this implant type (BAST), because stresses within the implant, the bridge and the bone are higher compared to prosthetic solutions where the implant remains outside of the lower arch.
Název v anglickém jazyce
Stress distribution within basal dental implants and on the interface to the bone. Influence of the design of the bridgework in the atrophied posterior mandible: the concept of supporting polygon.
Popis výsledku anglicky
This study analyses the force transfer and stress distribution of an implant supported circular bridge with rectangular crossection 3x3.5mm bridge in the atrophied mandible and considers two different designs for the bridge in the posterior mandible. Asa result we can conclude that the direct (straight) connection between the posterior implant in the mandible and the bridge is from the biomechanic point of view the least desireable solution for this implant type (BAST), because stresses within the implant, the bridge and the bone are higher compared to prosthetic solutions where the implant remains outside of the lower arch.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BO - Biofyzika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Cranio-maxillofacial Implant Directions
ISSN
1864-1199
e-ISSN
—
Svazek periodika
6
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
14
Strana od-do
43-56
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—