Thermomechanical fatigue test of cast iron GGG SiMo 4.05 and its numerical evaluation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F11%3A00186897" target="_blank" >RIV/68407700:21220/11:00186897 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Thermomechanical fatigue test of cast iron GGG SiMo 4.05 and its numerical evaluation
Popis výsledku v původním jazyce
Evaluation of uniaxial thermomechanical fatigue (TMF) test of cast iron GGG SiMo 4.05 is presented. The rod specimen is fixed into Coffin apparatus and cyclically heated and cooled until the rupture. The mutual approach of specimen's ends is measured. The dependence mechanical strain range - cycles to failure is obtained. Temperature along the specimen isn't constant in the same time. Evaluated strain is "average". The general usage of such tests is problematical. It was proposed methodology that generalizes the results of such TMF tests. The principle of this methodology is finite element simulation of real test. Local strain range is determined in the middle of the specimen. This is the typical location of the rupture. Computed local mechanical strain range is assigned to experimentally obtained cycles to failure. Localized lifetime curve is obtained. The proposed methodology allows the evaluation of TMF test on Coffin apparatus for more general application.
Název v anglickém jazyce
Thermomechanical fatigue test of cast iron GGG SiMo 4.05 and its numerical evaluation
Popis výsledku anglicky
Evaluation of uniaxial thermomechanical fatigue (TMF) test of cast iron GGG SiMo 4.05 is presented. The rod specimen is fixed into Coffin apparatus and cyclically heated and cooled until the rupture. The mutual approach of specimen's ends is measured. The dependence mechanical strain range - cycles to failure is obtained. Temperature along the specimen isn't constant in the same time. Evaluated strain is "average". The general usage of such tests is problematical. It was proposed methodology that generalizes the results of such TMF tests. The principle of this methodology is finite element simulation of real test. Local strain range is determined in the middle of the specimen. This is the typical location of the rupture. Computed local mechanical strain range is assigned to experimentally obtained cycles to failure. Localized lifetime curve is obtained. The proposed methodology allows the evaluation of TMF test on Coffin apparatus for more general application.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JL - Únava materiálu a lomová mechanika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/1M0568" target="_blank" >1M0568: Výzkumné centrum spalovacích motorů a automobilů Josefa Božka II</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Fatigue Design 2011 Recueil de conférences Conference Proceedings
ISBN
978-2-85400-946-0
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
"nečíslov. (ArtNo=W2.5)"
Název nakladatele
Centre technique des industries mécaniques
Místo vydání
Senlis
Místo konání akce
Senlis
Datum konání akce
23. 11. 2011
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—