Neutron Sources for Test and Calibration of Neutron Detectors for Space Research
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F12%3A00191726" target="_blank" >RIV/68407700:21220/12:00191726 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61389005:_____/12:00388172 RIV/26722445:_____/12:#0000700 RIV/68407700:21670/12:00191726
Výsledek na webu
<a href="http://proceedings.aip.org/resource/2/apcpcs/1423/1/446_1" target="_blank" >http://proceedings.aip.org/resource/2/apcpcs/1423/1/446_1</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1063/1.3688844" target="_blank" >10.1063/1.3688844</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Neutron Sources for Test and Calibration of Neutron Detectors for Space Research
Popis výsledku v původním jazyce
This work reports on the current status of neutron sources in the Czech Republic as calibrated and ESA compliant stations for space related applications such as the testing and calibration of neutron detectors and neutron sensitive devices as well as forstudies of radiation effects of electric and electronic components. The work was carried out as part of the preparatory accession activities of the Czech Republic with ESA. The goal and one of the tasks is to test and evaluate neutron sensitive devices,both conventional and prototypes, developed at ESA and at the IEAP CTU Prague. The facilities consist of both fast and thermal neutron sources providing testing and absolute calibration of a wide range of neutron detectors. The evaluation and calibration of the sources were carried out in cooperation with the Nuclear Physics Institute, Academy of Sciences of the Czech Republic, the Research Center Rez, and the Czech Metrology Institute in Prague
Název v anglickém jazyce
Neutron Sources for Test and Calibration of Neutron Detectors for Space Research
Popis výsledku anglicky
This work reports on the current status of neutron sources in the Czech Republic as calibrated and ESA compliant stations for space related applications such as the testing and calibration of neutron detectors and neutron sensitive devices as well as forstudies of radiation effects of electric and electronic components. The work was carried out as part of the preparatory accession activities of the Czech Republic with ESA. The goal and one of the tasks is to test and evaluate neutron sensitive devices,both conventional and prototypes, developed at ESA and at the IEAP CTU Prague. The facilities consist of both fast and thermal neutron sources providing testing and absolute calibration of a wide range of neutron detectors. The evaluation and calibration of the sources were carried out in cooperation with the Nuclear Physics Institute, Academy of Sciences of the Czech Republic, the Research Center Rez, and the Czech Metrology Institute in Prague
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IX LATIN AMERICAN SYMPOSIUM ON NUCLEAR PHYSICS AND APPLICATIONS
ISBN
978-0-7354-1003-9
ISSN
0094-243X
e-ISSN
—
Počet stran výsledku
7
Strana od-do
446-452
Název nakladatele
American Institute of Physics
Místo vydání
Melville, New York
Místo konání akce
Quito
Datum konání akce
18. 7. 2011
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000302767500071