Ex vivo coronary stent implantation evaluated with digital image correlation
Popis výsledku v původním jazyce
Intracoronary stenting (PCI) has become standard revascularization technique to reopen blocked arteries. Although significant progress in stenting technology and implantation techniques has been made a number of problems remain. Specifically, stent sizing and inflation pressures are still a matter of scientific debates. Despite a large number of biomechanical computational simulations experimental data are rare, likely due to technical difficulties to measure dilatation pressures and coronary dimensionsin the same settings. Our study shows that valuable data can be obtained by employing digital image correlation for 3D strain measurement during stent inflation ex-vivo that can provide further insight into the stent-artery wall interactions.
Název v anglickém jazyce
Ex vivo coronary stent implantation evaluated with digital image correlation
Popis výsledku anglicky
Intracoronary stenting (PCI) has become standard revascularization technique to reopen blocked arteries. Although significant progress in stenting technology and implantation techniques has been made a number of problems remain. Specifically, stent sizing and inflation pressures are still a matter of scientific debates. Despite a large number of biomechanical computational simulations experimental data are rare, likely due to technical difficulties to measure dilatation pressures and coronary dimensionsin the same settings. Our study shows that valuable data can be obtained by employing digital image correlation for 3D strain measurement during stent inflation ex-vivo that can provide further insight into the stent-artery wall interactions.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JJ - Ostatní materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Experimental Mechanics
ISSN
0014-4851
e-ISSN
—
Svazek periodika
52
Číslo periodika v rámci svazku
9
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
4
Strana od-do
1555-1558
Kód UT WoS článku
000310892100025