Accuracy of tracer stimulus response experiments in laminar flows
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F12%3A00196483" target="_blank" >RIV/68407700:21220/12:00196483 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61388998:_____/12:00382230
Výsledek na webu
<a href="http://www.sciencedirect.com/science/article/pii/S001793101200470X" target="_blank" >http://www.sciencedirect.com/science/article/pii/S001793101200470X</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.ijheatmasstransfer.2012.06.042" target="_blank" >10.1016/j.ijheatmasstransfer.2012.06.042</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Accuracy of tracer stimulus response experiments in laminar flows
Popis výsledku v původním jazyce
Experimental identification of the residence time distribution (RTD) characteristics for steady (or pulsatile) flows using a stimulus response technique, for example using tracers, is very demanding. The accuracy of the RTD characteristics depends on theprecise distribution of the injected tracer via the injection modulus, and also on appropriate design of the detector. The performance of various modifications of the injection modulus and of the conductivity probe is assessed using the simplest possible system - a straight pipe and fully developed laminar flow. This comparison is made via the deviation of the experimental values for the time of the first appearance and the mean residence time from the in theoretical values. We find the optimal configuration of the injection modulus and the conductivity probe for laminar and convection-dominated flow in a straight rigid pipe.
Název v anglickém jazyce
Accuracy of tracer stimulus response experiments in laminar flows
Popis výsledku anglicky
Experimental identification of the residence time distribution (RTD) characteristics for steady (or pulsatile) flows using a stimulus response technique, for example using tracers, is very demanding. The accuracy of the RTD characteristics depends on theprecise distribution of the injected tracer via the injection modulus, and also on appropriate design of the detector. The performance of various modifications of the injection modulus and of the conductivity probe is assessed using the simplest possible system - a straight pipe and fully developed laminar flow. This comparison is made via the deviation of the experimental values for the time of the first appearance and the mean residence time from the in theoretical values. We find the optimal configuration of the injection modulus and the conductivity probe for laminar and convection-dominated flow in a straight rigid pipe.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal of Heat and Mass Transfer
ISSN
0017-9310
e-ISSN
—
Svazek periodika
55
Číslo periodika v rámci svazku
23-24
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
5
Strana od-do
6458-6462
Kód UT WoS článku
000309042300016
EID výsledku v databázi Scopus
—