The reduction of convective heat output at panel radiators
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F12%3A00200919" target="_blank" >RIV/68407700:21220/12:00200919 - isvavai.cz</a>
Výsledek na webu
<a href="http://stc.fs.cvut.cz" target="_blank" >http://stc.fs.cvut.cz</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The reduction of convective heat output at panel radiators
Popis výsledku v původním jazyce
The main aim of the research work is to describe temperature and velocity fields above the panel radiator fitted with non-standard (or design) covering grids with various flow cross-section and the subsequent effect at an air flow throughout the room. The effect of flow cross-section and shape of openings of panel radiators covering grids at their heat output was determined experimentally. The other experiment dealt with description of velocity field above the covering grid, using the method of particleimage velocimetry (PIV). The results are presented in a graphic form as a heat output decrease depending on parameters of the covering grid and in the form of velocity vectors placed in two orthogonal planes. Based on experimentally obtained data, the mathematical model will be verified. Then a computer fluid dynamics (CFD) will be used to simulate both temperature and velocity fields above the panel radiator and in the room.
Název v anglickém jazyce
The reduction of convective heat output at panel radiators
Popis výsledku anglicky
The main aim of the research work is to describe temperature and velocity fields above the panel radiator fitted with non-standard (or design) covering grids with various flow cross-section and the subsequent effect at an air flow throughout the room. The effect of flow cross-section and shape of openings of panel radiators covering grids at their heat output was determined experimentally. The other experiment dealt with description of velocity field above the covering grid, using the method of particleimage velocimetry (PIV). The results are presented in a graphic form as a heat output decrease depending on parameters of the covering grid and in the form of velocity vectors placed in two orthogonal planes. Based on experimentally obtained data, the mathematical model will be verified. Then a computer fluid dynamics (CFD) will be used to simulate both temperature and velocity fields above the panel radiator and in the room.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Sborník STČ 2012
ISBN
978-80-01-04796-5
ISSN
—
e-ISSN
—
Počet stran výsledku
10
Strana od-do
1-10
Název nakladatele
České vysoké učení technické v Praze, Fakulta strojní
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
28. 3. 2012
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—