Wet steam energy loss and related Baumann rule in a 1000 MW nuclear and a 210 MW fossil-fired LP steam turbine
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F12%3A00203373" target="_blank" >RIV/68407700:21220/12:00203373 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Wet steam energy loss and related Baumann rule in a 1000 MW nuclear and a 210 MW fossil-fired LP steam turbine
Popis výsledku v původním jazyce
This paper presents the results of a computational analysis of the wet steam energy loss occurring in a 210 MW fossil-fired and a 1000 MW nuclear LP steam turbine. The turbines operate under considerably different conditions as regards pressure level inthe droplet nucleation zone, exit moisture level and droplet size spectra determined from optical extinction measurements. An evaluation of the basic wetness energy losses has been carried out including the thermodynamic loss, drag loss of the fine and coarse droplets, impact loss, collected water loss, centrifuging loss and exit loss. A statistical 2D evaluation method has been employed throughout the computational simulation of the loss. The objective of the analysis was to determine whether an equilibrium based Baumann factor of order 0.6 can be used for predicting the wet steam loss.
Název v anglickém jazyce
Wet steam energy loss and related Baumann rule in a 1000 MW nuclear and a 210 MW fossil-fired LP steam turbine
Popis výsledku anglicky
This paper presents the results of a computational analysis of the wet steam energy loss occurring in a 210 MW fossil-fired and a 1000 MW nuclear LP steam turbine. The turbines operate under considerably different conditions as regards pressure level inthe droplet nucleation zone, exit moisture level and droplet size spectra determined from optical extinction measurements. An evaluation of the basic wetness energy losses has been carried out including the thermodynamic loss, drag loss of the fine and coarse droplets, impact loss, collected water loss, centrifuging loss and exit loss. A statistical 2D evaluation method has been employed throughout the computational simulation of the loss. The objective of the analysis was to determine whether an equilibrium based Baumann factor of order 0.6 can be used for predicting the wet steam loss.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP101%2F11%2F1593" target="_blank" >GAP101/11/1593: Výzkum nerovnovážné kondenzace páry - nový přístup</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
The Baumann Centenary Conference on The Science and Engineering of Non-Equilibrium Wet Steam Flows in Steam Turbines
ISBN
978-0-903428-35-4
ISSN
—
e-ISSN
—
Počet stran výsledku
15
Strana od-do
—
Název nakladatele
Cambridge University Engineering Department
Místo vydání
Cambridge
Místo konání akce
Cambridge
Datum konání akce
10. 9. 2012
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—