SCT mockup for Air cooling
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F13%3A00210960" target="_blank" >RIV/68407700:21220/13:00210960 - isvavai.cz</a>
Výsledek na webu
<a href="http://fyzika.fs.cvut.cz/collaborationCERN.php" target="_blank" >http://fyzika.fs.cvut.cz/collaborationCERN.php</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
SCT mockup for Air cooling
Popis výsledku v původním jazyce
Experimental setup with AIRCOOLER_I had been constructed in order to evaluate the performance of vortex tubes, located inside the AIRCOOLER, with high impedance (high pressure drop) structure at the output of the chilled air. The input compressed air (8bara) which was precooled in the water-air heat exchanger was divided into hot and cold streams by the vortex tubes. The cold stream at the temperature of -30°C was cooling down the 1.7m long thin-wall stainless steel tube ID 2mm. The volumetric flow rateof the cooled air was measured by the IST thermal flowmeter which had been calibrated against the precise anemometer TESTO 416. The cooling box was equipped with 3 pressure gauges and number of temperature sensors. The temperature along the stainless-steel tube was measured using 4 Pt1000 sensors. The pressure drop was measured by differential pressure sensor. As a readout for the sensors the ELMB with Kvaser USB/CAN adaptor were employed. For the data storage and visualization the PVSS
Název v anglickém jazyce
SCT mockup for Air cooling
Popis výsledku anglicky
Experimental setup with AIRCOOLER_I had been constructed in order to evaluate the performance of vortex tubes, located inside the AIRCOOLER, with high impedance (high pressure drop) structure at the output of the chilled air. The input compressed air (8bara) which was precooled in the water-air heat exchanger was divided into hot and cold streams by the vortex tubes. The cold stream at the temperature of -30°C was cooling down the 1.7m long thin-wall stainless steel tube ID 2mm. The volumetric flow rateof the cooled air was measured by the IST thermal flowmeter which had been calibrated against the precise anemometer TESTO 416. The cooling box was equipped with 3 pressure gauges and number of temperature sensors. The temperature along the stainless-steel tube was measured using 4 Pt1000 sensors. The pressure drop was measured by differential pressure sensor. As a readout for the sensors the ELMB with Kvaser USB/CAN adaptor were employed. For the data storage and visualization the PVSS
Klasifikace
Druh
G<sub>funk</sub> - Funkční vzorek
CEP obor
BJ - Termodynamika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LG13009" target="_blank" >LG13009: Mezinárodní experiment ATLAS-CERN</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Interní identifikační kód produktu
SCT_AirCool2013
Číselná identifikace
—
Technické parametry
3m x 0,5m x 0,4m, osazeno senzory a eletronikou
Ekonomické parametry
60000 Kč
Kategorie aplik. výsledku dle nákladů
—
IČO vlastníka výsledku
68407700
Název vlastníka
ČVUT FSI
Stát vlastníka
CZ - Česká republika
Druh možnosti využití
P - Využití výsledku jiným subjektem je v některých případech možné bez nabytí licence
Požadavek na licenční poplatek
Z - Poskytovatel licence na výsledek nepožaduje v některých případech licenční poplatek
Adresa www stránky s výsledkem
—