Measurement Of O2 In A Combustion Chamber With An Analysis Of The Burn Out Ratio
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F13%3A00216765" target="_blank" >RIV/68407700:21220/13:00216765 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Measurement Of O2 In A Combustion Chamber With An Analysis Of The Burn Out Ratio
Popis výsledku v původním jazyce
An aim of this experimental research work was to achieve more detailed information about the combustion process in pulverized coal boilers. An O2 analyser was developed and manufactured for the measurement of O2 volumetric concentration directly in the combustion chamber. The volumetric concentration of O2 in the combustion chamber is important information about the burn out ratio, quality of combustion and the space distribution of the flame. The uniformity of the flame or the even distribution of thecombustion parameters could be a possible way how to move to satisfy new emission limits. Measured parameters of the combustion process could be used for the control system of the boiler. The O2 analyser was manufactured for the permanent measurement with acceptable results. The measurement of the air excess ratio in the combustion chamber shows that for the left and right side of the combustion chamber could be highly non-uniform. For correct interpretation of the air excess ratio measu
Název v anglickém jazyce
Measurement Of O2 In A Combustion Chamber With An Analysis Of The Burn Out Ratio
Popis výsledku anglicky
An aim of this experimental research work was to achieve more detailed information about the combustion process in pulverized coal boilers. An O2 analyser was developed and manufactured for the measurement of O2 volumetric concentration directly in the combustion chamber. The volumetric concentration of O2 in the combustion chamber is important information about the burn out ratio, quality of combustion and the space distribution of the flame. The uniformity of the flame or the even distribution of thecombustion parameters could be a possible way how to move to satisfy new emission limits. Measured parameters of the combustion process could be used for the control system of the boiler. The O2 analyser was manufactured for the permanent measurement with acceptable results. The measurement of the air excess ratio in the combustion chamber shows that for the left and right side of the combustion chamber could be highly non-uniform. For correct interpretation of the air excess ratio measu
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/TA03020995" target="_blank" >TA03020995: Výzkum progresivní metody řízení spalování pevných paliv</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of Abstracts ERIN 2013
ISBN
978-80-227-3934-4
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
Slovak University of Technology in Bratislava
Místo vydání
Bratislava
Místo konání akce
Častá-Papiernička
Datum konání akce
15. 5. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—