Counter-flow Cooling Tower Test Cell
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F14%3A00216902" target="_blank" >RIV/68407700:21220/14:00216902 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.ptte.cz" target="_blank" >http://www.ptte.cz</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1051/epjconf/20146702024" target="_blank" >10.1051/epjconf/20146702024</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Counter-flow Cooling Tower Test Cell
Popis výsledku v původním jazyce
The article contains a design of functional experimental model of a cross-flow mechanical draft cooling tower and results and outcomes from the measurements. This device is primarily used for measuring performance characteristics of cooling fills, but with a simple rebuild, it can be used for measuring other thermodynamic processes, which take part in the so called wet cooling. The main advantages of the particular test cell lies in the accuracy, size and the possibility of changing the water distribution level. This feature is very useful for measurements of the fills of different heights without the influence of spray and rain zone. The functionality of this testing cell has been experimentally verified during the assembly and the data from the measurement of common cooling film fills has been compared against the results taken from another experimental line. For the purpose of evaluating the gathered data, computational scripts were created in the numerical computing environment MAT
Název v anglickém jazyce
Counter-flow Cooling Tower Test Cell
Popis výsledku anglicky
The article contains a design of functional experimental model of a cross-flow mechanical draft cooling tower and results and outcomes from the measurements. This device is primarily used for measuring performance characteristics of cooling fills, but with a simple rebuild, it can be used for measuring other thermodynamic processes, which take part in the so called wet cooling. The main advantages of the particular test cell lies in the accuracy, size and the possibility of changing the water distribution level. This feature is very useful for measurements of the fills of different heights without the influence of spray and rain zone. The functionality of this testing cell has been experimentally verified during the assembly and the data from the measurement of common cooling film fills has been compared against the results taken from another experimental line. For the purpose of evaluating the gathered data, computational scripts were created in the numerical computing environment MAT
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/TE01020036" target="_blank" >TE01020036: Pokročilé technologie pro výrobu tepla a elektřiny</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
EFM 2013; Experimental Fluid Mechanics 2013
ISBN
978-80-260-5375-0
ISSN
2101-6275
e-ISSN
—
Počet stran výsledku
5
Strana od-do
—
Název nakladatele
Technical University of Liberec
Místo vydání
Liberec
Místo konání akce
Kutná Hora
Datum konání akce
19. 11. 2013
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
000343672100027