PASSIVE ELEMENTS FOR PRECISE DIRECTION AND MANAGEMENT OF AIR IN DATA RACKS
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F14%3A00217886" target="_blank" >RIV/68407700:21220/14:00217886 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
PASSIVE ELEMENTS FOR PRECISE DIRECTION AND MANAGEMENT OF AIR IN DATA RACKS
Popis výsledku v původním jazyce
Abstract: The goal of the presented work is to enable the increase of energy load in one data rack up to 15kW. The work aims to find and subsequently optimize such passive elements for directing the air flow inside the data rack, which lead to the mass flow rate increase in the data rack while keeping the pressure loss. Target value of the mass flow rate in the data rack was 1 m3s-1 of air assuming a fifteen-degree temperature drop on IT devices fitted in the data rack. The work resulted in two optimized deflectors that serve for directing the air flow through the floor to the front of the IT device. Further increase of the mass flow rate in the data rack was solved with the help of additional side zones. All passive elements were first verified with the help of numerical simulations and subsequently also by experiments. The final optimized variant indicates, at the same pressure drop, an increase of the mass flow rate by 79%; the resultant mass flow rate of 0.97 m3s-1 enables to fit t
Název v anglickém jazyce
PASSIVE ELEMENTS FOR PRECISE DIRECTION AND MANAGEMENT OF AIR IN DATA RACKS
Popis výsledku anglicky
Abstract: The goal of the presented work is to enable the increase of energy load in one data rack up to 15kW. The work aims to find and subsequently optimize such passive elements for directing the air flow inside the data rack, which lead to the mass flow rate increase in the data rack while keeping the pressure loss. Target value of the mass flow rate in the data rack was 1 m3s-1 of air assuming a fifteen-degree temperature drop on IT devices fitted in the data rack. The work resulted in two optimized deflectors that serve for directing the air flow through the floor to the front of the IT device. Further increase of the mass flow rate in the data rack was solved with the help of additional side zones. All passive elements were first verified with the help of numerical simulations and subsequently also by experiments. The final optimized variant indicates, at the same pressure drop, an increase of the mass flow rate by 79%; the resultant mass flow rate of 0.97 m3s-1 enables to fit t
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BK - Mechanika tekutin
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/TA01010184" target="_blank" >TA01010184: Výzkum a vývoj řešení rozvaděčových, chladících a transportních systémů pro datová centra</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
20 th International Conference Engineering Mechanics 2014
ISBN
978-80-214-4871-1
ISSN
1805-8248
e-ISSN
—
Počet stran výsledku
4
Strana od-do
440-443
Název nakladatele
Brno University of Technology
Místo vydání
Brno
Místo konání akce
Svratka
Datum konání akce
12. 5. 2014
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—