Evaluation of Unalloyed Steel Corrosion of industrial pipeline
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F14%3A00218748" target="_blank" >RIV/68407700:21220/14:00218748 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Evaluation of Unalloyed Steel Corrosion of industrial pipeline
Popis výsledku v původním jazyce
The main aim of the presented paper was to analyse of corrosion damage of unalloyed steel pipe. The investigated pipe was the operating part of the pipeline in the heating plant. Corrosion of the inner wall of a natural gas pipeline may occur when the wall is exposed to water and contaminants in the gas, such as O2, H2S, CO2 or chlorides. Corrosion damage of pipe, which was made of steel 12021.1 was subsequently investigated by means of stereo microscopy and optical microscopy. In the experimental part,the pipe was sectioned, grinded, polished and etched. The structure of the pipe is ferrite-pearlite. In relation to the pipe, the occurrence of corrosion which was identified is commonly called as pitting. It is a dangerous kind of corrosion. The corrosion effect involves penetration of the pipe wall and then it is necessary to weld affected pipes. In addition, corrosion was observed for the outside of the pipe.
Název v anglickém jazyce
Evaluation of Unalloyed Steel Corrosion of industrial pipeline
Popis výsledku anglicky
The main aim of the presented paper was to analyse of corrosion damage of unalloyed steel pipe. The investigated pipe was the operating part of the pipeline in the heating plant. Corrosion of the inner wall of a natural gas pipeline may occur when the wall is exposed to water and contaminants in the gas, such as O2, H2S, CO2 or chlorides. Corrosion damage of pipe, which was made of steel 12021.1 was subsequently investigated by means of stereo microscopy and optical microscopy. In the experimental part,the pipe was sectioned, grinded, polished and etched. The structure of the pipe is ferrite-pearlite. In relation to the pipe, the occurrence of corrosion which was identified is commonly called as pitting. It is a dangerous kind of corrosion. The corrosion effect involves penetration of the pipe wall and then it is necessary to weld affected pipes. In addition, corrosion was observed for the outside of the pipe.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JG - Hutnictví, kovové materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1207" target="_blank" >LO1207: Podpora udržitelnosti Inovačního centra diagnostiky a aplikace materiálů na ČVUT-FS v Praze</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Hutnické listy
ISSN
0018-8069
e-ISSN
—
Svazek periodika
LXVII
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
4
Strana od-do
9-12
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—