An investigation of the influence of cart ilaginous tissue microst ructure on its local mechanical properties
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F14%3A00223903" target="_blank" >RIV/68407700:21220/14:00223903 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.zcu.cz/pracoviste/vyd/online/Humanic_web.pdf" target="_blank" >http://www.zcu.cz/pracoviste/vyd/online/Humanic_web.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
An investigation of the influence of cart ilaginous tissue microst ructure on its local mechanical properties
Popis výsledku v původním jazyce
The research on mechanical properties of a cartilaginous endplate (CEP) seems to be more actual in current biomechanics of a spine. Mechanical properties of the cartilaginous endplate are presented with large range of values in the literature. Elastic moduli are given in the range from 5 MPa to 10 GPa. Which raises the following questions: What causes this large range of values? Is it an erroneously performed experiment? Is it a poorly identified endplate? Is it an inner microstructure of the endplate that causes large range of measured values? We decided to investigate mechanical properties depending on inner microstructure of CEP and thereby detect possible source of scattering of results.
Název v anglickém jazyce
An investigation of the influence of cart ilaginous tissue microst ructure on its local mechanical properties
Popis výsledku anglicky
The research on mechanical properties of a cartilaginous endplate (CEP) seems to be more actual in current biomechanics of a spine. Mechanical properties of the cartilaginous endplate are presented with large range of values in the literature. Elastic moduli are given in the range from 5 MPa to 10 GPa. Which raises the following questions: What causes this large range of values? Is it an erroneously performed experiment? Is it a poorly identified endplate? Is it an inner microstructure of the endplate that causes large range of measured values? We decided to investigate mechanical properties depending on inner microstructure of CEP and thereby detect possible source of scattering of results.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
EI - Biotechnologie a bionika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů