Experimental investigation of the steam wetness in a 1000 MW steam turbine
Popis výsledku v původním jazyce
The aim of this paper is to introduce the experimental data of the wetness distribution achieved in the year 2015 in front of and behind the last stage of the 1000MW steam turbine in the power-plant Temelín (ETE). Two different optical probes developed on CTU were used. In the first time in the Czechia a pneumatic and optic measurement of the wet steam flow field in the front of the last stage of the nuclear power-station steam turbine was provided. This unique measurement opportunity brought a lot of of new information for the manufacturer and operator of the steam turbine and valuable experimental data for the phase transition modelling in the wet steam flow. The experimental measurement was done in cooperation with Doosan Škoda Power s.r.o. (DSP
Název v anglickém jazyce
Experimental investigation of the steam wetness in a 1000 MW steam turbine
Popis výsledku anglicky
The aim of this paper is to introduce the experimental data of the wetness distribution achieved in the year 2015 in front of and behind the last stage of the 1000MW steam turbine in the power-plant Temelín (ETE). Two different optical probes developed on CTU were used. In the first time in the Czechia a pneumatic and optic measurement of the wet steam flow field in the front of the last stage of the nuclear power-station steam turbine was provided. This unique measurement opportunity brought a lot of of new information for the manufacturer and operator of the steam turbine and valuable experimental data for the phase transition modelling in the wet steam flow. The experimental measurement was done in cooperation with Doosan Škoda Power s.r.o. (DSP
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP101%2F11%2F1593" target="_blank" >GAP101/11/1593: Výzkum nerovnovážné kondenzace páry - nový přístup</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
EPJ web of conferences
ISSN
2101-6275
e-ISSN
—
Svazek periodika
114
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
FR - Francouzská republika
Počet stran výsledku
6
Strana od-do
393-398
Kód UT WoS článku
000358249900037
EID výsledku v databázi Scopus
2-s2.0-84974806710