Downscale Application of Boiler Thermal Calculation Approach
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F16%3A00243301" target="_blank" >RIV/68407700:21220/16:00243301 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21720/16:00243301
Výsledek na webu
<a href="http://hrcak.srce.hr/index.php?show=clanak&id_clanak_jezik=228330" target="_blank" >http://hrcak.srce.hr/index.php?show=clanak&id_clanak_jezik=228330</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Downscale Application of Boiler Thermal Calculation Approach
Popis výsledku v původním jazyce
Commonly used thermal calculation methods are intended primarily for large scale boilers. Hot water small scale boilers, which are commonly used for home heating, have many specifics that distinguish them from large scale boilers especially steam boilers. This paper is focused on application of thermal calculation procedure that is designed for large scale boilers, on a small scale boiler for biomass combustion of load capacity 25 kW. Special issue solved here is influence of formation of deposits on heat exchanging surfaces on efficiency of heat transfer and on overall boiler efficiency. In the paper are presented results of mathematical model created for this purpose and its verification by experimental measurement in this specific boiler.
Název v anglickém jazyce
Downscale Application of Boiler Thermal Calculation Approach
Popis výsledku anglicky
Commonly used thermal calculation methods are intended primarily for large scale boilers. Hot water small scale boilers, which are commonly used for home heating, have many specifics that distinguish them from large scale boilers especially steam boilers. This paper is focused on application of thermal calculation procedure that is designed for large scale boilers, on a small scale boiler for biomass combustion of load capacity 25 kW. Special issue solved here is influence of formation of deposits on heat exchanging surfaces on efficiency of heat transfer and on overall boiler efficiency. In the paper are presented results of mathematical model created for this purpose and its verification by experimental measurement in this specific boiler.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED2.1.00%2F03.0091" target="_blank" >ED2.1.00/03.0091: Univerzitní centrum energeticky efektivních budov (UCEEB)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
THE HOLISTIC APPROACH TO ENVIRONMENT
ISSN
1848-0071
e-ISSN
—
Svazek periodika
6
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
HR - Chorvatská republika
Počet stran výsledku
8
Strana od-do
89-96