Effect of perivascular tissue on inflation-extension behavior of abdominal aorta
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F16%3A00306249" target="_blank" >RIV/68407700:21220/16:00306249 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11120/16:43912534
Výsledek na webu
<a href="https://www.eccomas2016.org/" target="_blank" >https://www.eccomas2016.org/</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Effect of perivascular tissue on inflation-extension behavior of abdominal aorta
Popis výsledku v původním jazyce
This study shows that the human perivascular adipose tissue can significantly affect mechanical response of the human abdominal aorta. Analytical model of incompressible bilayer thick-walled closed cylindrical tube has been created and subsequently used to simulate the inflation-extension response of the aorta surrounded with adipose tissue. The inner layer, abdominal aorta, was assumed to exhibit residual stresses. The material of this layer was considered as anisotropic and was described by hyperelastic nonlinear constitutive model. The outer layer, fat tissue, was considered to be a hyperelastic isotropic material which does not exhibit residual stress. The outer radius of the aorta and inner radius of the external fatty tube were considered to be equal during the pressurization and axial stretch. The inflation-extension response of bilayer tube was compared with one-layer representing only the abdominal aorta.
Název v anglickém jazyce
Effect of perivascular tissue on inflation-extension behavior of abdominal aorta
Popis výsledku anglicky
This study shows that the human perivascular adipose tissue can significantly affect mechanical response of the human abdominal aorta. Analytical model of incompressible bilayer thick-walled closed cylindrical tube has been created and subsequently used to simulate the inflation-extension response of the aorta surrounded with adipose tissue. The inner layer, abdominal aorta, was assumed to exhibit residual stresses. The material of this layer was considered as anisotropic and was described by hyperelastic nonlinear constitutive model. The outer layer, fat tissue, was considered to be a hyperelastic isotropic material which does not exhibit residual stress. The outer radius of the aorta and inner radius of the external fatty tube were considered to be equal during the pressurization and axial stretch. The inflation-extension response of bilayer tube was compared with one-layer representing only the abdominal aorta.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JJ - Ostatní materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
ECCOMAS Congress 2016
ISBN
978-618-82844-0-1
ISSN
—
e-ISSN
—
Počet stran výsledku
9
Strana od-do
6616-6624
Název nakladatele
ECCOMAS
Místo vydání
Paříž
Místo konání akce
Chersonisos
Datum konání akce
5. 6. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—