Comparison of the effect of optical properties of liquid on the accuracy of measurement by PIV method
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F16%3A00306263" target="_blank" >RIV/68407700:21220/16:00306263 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of the effect of optical properties of liquid on the accuracy of measurement by PIV method
Popis výsledku v původním jazyce
The paper is concerned on the quantification of the error measurement by PIV method. Error is caused by different optical properties of liquid and the model of stenosis. Different optical properties of two materials cause light refraction at the interface of the materials. This light refraction causes the interference of the measurement that unable the measurement nearby the wall. Further problem is the optical deformation of the scan area that is caused by the curvature of the model. This deformation causes the error in the measurement. Elimination of the negative effects from the measurement is performed by comparing the refractive index of the liquid and the model of stenosis. Change of refractive index is performed by adding iodide sodium to the liquid. Measurement by PIV method with solution of iodide sodium and distilled water is done for the error quantification.
Název v anglickém jazyce
Comparison of the effect of optical properties of liquid on the accuracy of measurement by PIV method
Popis výsledku anglicky
The paper is concerned on the quantification of the error measurement by PIV method. Error is caused by different optical properties of liquid and the model of stenosis. Different optical properties of two materials cause light refraction at the interface of the materials. This light refraction causes the interference of the measurement that unable the measurement nearby the wall. Further problem is the optical deformation of the scan area that is caused by the curvature of the model. This deformation causes the error in the measurement. Elimination of the negative effects from the measurement is performed by comparing the refractive index of the liquid and the model of stenosis. Change of refractive index is performed by adding iodide sodium to the liquid. Measurement by PIV method with solution of iodide sodium and distilled water is done for the error quantification.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BK - Mechanika tekutin
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Studentská tvůrčí činnost 2016 - sborník konference
ISBN
978-80-01-05929-6
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
—
Název nakladatele
České vysoké učení technické v Praze, Fakulta strojní
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
19. 4. 2016
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—