Modeling of Electrical Resistance Measuring Method for Sensing Damage and Deformation in CFRP Composites
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F17%3A00312040" target="_blank" >RIV/68407700:21220/17:00312040 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21230/17:00312040
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Modeling of Electrical Resistance Measuring Method for Sensing Damage and Deformation in CFRP Composites
Popis výsledku v původním jazyce
This paper presents a study on electrical resistance (ER) measurement on unidirectional CFRP composite beam during cyclic flexural loading. ER measurement was conducted in the transverse direction to the fiber direction. Three measuring configuration, each in two copies were measured during shutdowns of loading. One measuring point was monitored by ER measurement also during cyclic loading. Artificial damage was created in a form of a cut in the middle of a specimen so that the cross section of the specimen was reduced. According to performed measurements further tests on possibility of damage detection during cyclic flexural loading by measuring ER in transversal direction must be performed. Possibility of fiber crack detection by presented type of measurement was confirmed.
Název v anglickém jazyce
Modeling of Electrical Resistance Measuring Method for Sensing Damage and Deformation in CFRP Composites
Popis výsledku anglicky
This paper presents a study on electrical resistance (ER) measurement on unidirectional CFRP composite beam during cyclic flexural loading. ER measurement was conducted in the transverse direction to the fiber direction. Three measuring configuration, each in two copies were measured during shutdowns of loading. One measuring point was monitored by ER measurement also during cyclic loading. Artificial damage was created in a form of a cut in the middle of a specimen so that the cross section of the specimen was reduced. According to performed measurements further tests on possibility of damage detection during cyclic flexural loading by measuring ER in transversal direction must be performed. Possibility of fiber crack detection by presented type of measurement was confirmed.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
—
OECD FORD obor
20505 - Composites (including laminates, reinforced plastics, cermets, combined natural and synthetic fibre fabrics; filled composites)
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů