In this work, we focus on an estimation of the measurement accuracy at each measured point using PIV method, a formulation of a suitable metric of the correlation plane and a definition of the dependency between specific metric and the measurement accuracy using the synthetic test so called Uniform flow test and algorithm called multi - step standard cross - correlation. The main contribution of this work is the correction of known metrics of the correlation plane called Primary peak ratio and Mutual information. The correction of these metrics involves the effect of particle displacements within the interrogation area and the effect of the size and the number of the particles on the evaluation of the metric. The result of this work is the functional dependency defining the relationship between the metric value and the accuracy of the PIV measurement.
Název v anglickém jazyce
Corrected Signal to noise ratio and Mutual information for accuracy determination in PIV
Popis výsledku anglicky
In this work, we focus on an estimation of the measurement accuracy at each measured point using PIV method, a formulation of a suitable metric of the correlation plane and a definition of the dependency between specific metric and the measurement accuracy using the synthetic test so called Uniform flow test and algorithm called multi - step standard cross - correlation. The main contribution of this work is the correction of known metrics of the correlation plane called Primary peak ratio and Mutual information. The correction of these metrics involves the effect of particle displacements within the interrogation area and the effect of the size and the number of the particles on the evaluation of the metric. The result of this work is the functional dependency defining the relationship between the metric value and the accuracy of the PIV measurement.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10305 - Fluids and plasma physics (including surface physics)
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
33rd conference with international participation Computational Mechanics 2017 - Extended Abstracts
ISBN
978-80-261-0748-4
ISSN
—
e-ISSN
—
Počet stran výsledku
100
Strana od-do
1-100
Název nakladatele
University of West Bohemia
Místo vydání
Pilsen
Místo konání akce
Špičák, Železná Ruda
Datum konání akce
6. 11. 2017
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—