Forced convection and heat transfer around a bounded cylinder.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F18%3A00315328" target="_blank" >RIV/68407700:21220/18:00315328 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1051/matecconf/201815702045" target="_blank" >http://dx.doi.org/10.1051/matecconf/201815702045</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1051/matecconf/201815702045" target="_blank" >10.1051/matecconf/201815702045</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Forced convection and heat transfer around a bounded cylinder.
Popis výsledku v původním jazyce
The article deals with the heat transfer solution in the fluid flow inside a pipe, the small tube is inserted into the pipe and its axis is perpendicular to the axis of the pipe. The fluid is water, the regime of the fluid flow is turbulent. The small tube is loaded by the internal source of the heat, the power of the source is constant and homogenous over the small tube surface and the cold water cools down the small tube. The analysis of the described problem helps to design the experimental model (the heat source above all) to validate the CFD results. The work included the numeric and analytic method. The model was prepared with the aim to investigate large amount of the variants of the geometric set up (the tube and pipe diameters ratio, i.g the geometrical aspect ratio, corresponding stabilization length of the pipe for given diameter), the flow properties (variation of the velocity values, i.g. Reynolds number) and the power of the heat source (ensuring the measurable differences of the temperatures on the tube surface, i.g. large Nusselt number). The effect of the constrained space has been observed and described, compare to the free fluid flow.
Název v anglickém jazyce
Forced convection and heat transfer around a bounded cylinder.
Popis výsledku anglicky
The article deals with the heat transfer solution in the fluid flow inside a pipe, the small tube is inserted into the pipe and its axis is perpendicular to the axis of the pipe. The fluid is water, the regime of the fluid flow is turbulent. The small tube is loaded by the internal source of the heat, the power of the source is constant and homogenous over the small tube surface and the cold water cools down the small tube. The analysis of the described problem helps to design the experimental model (the heat source above all) to validate the CFD results. The work included the numeric and analytic method. The model was prepared with the aim to investigate large amount of the variants of the geometric set up (the tube and pipe diameters ratio, i.g the geometrical aspect ratio, corresponding stabilization length of the pipe for given diameter), the flow properties (variation of the velocity values, i.g. Reynolds number) and the power of the heat source (ensuring the measurable differences of the temperatures on the tube surface, i.g. large Nusselt number). The effect of the constrained space has been observed and described, compare to the free fluid flow.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20301 - Mechanical engineering
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
XXII Slovak_Polish Scientific Conference Machine Modelling and Simulation Proceedings
ISBN
—
ISSN
2261-236X
e-ISSN
2261-236X
Počet stran výsledku
8
Strana od-do
—
Název nakladatele
EDP Sciences
Místo vydání
Les Ulis Cedex A
Místo konání akce
Sklené Teplice
Datum konání akce
5. 9. 2017
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—