Diamond detectors for high energy physics experiments
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F18%3A00321659" target="_blank" >RIV/68407700:21220/18:00321659 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21340/18:00321659
Výsledek na webu
<a href="http://dx.doi.org/10.1088/1748-0221/13/01/C01029" target="_blank" >http://dx.doi.org/10.1088/1748-0221/13/01/C01029</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1748-0221/13/01/C01029" target="_blank" >10.1088/1748-0221/13/01/C01029</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Diamond detectors for high energy physics experiments
Popis výsledku v původním jazyce
Beam test results of the radiation tolerance study of chemical vapour deposition (CVD) diamond against different particle species and energies is presented. We also present beam test results on the independence of signal size on incident particle rate in charged particle detectors based on un-irradiated and irradiated poly-crystalline CVD diamond over a range of particle fluxes from 2 kHz/cm(2) to 10 MHz/cm(2). The pulse height of the sensors was measured with readout electronics with a peaking time of 6 ns. In addition functionality of poly-crystalline CVD diamond 3D devices was demonstrated in beam tests and 3D diamond detectors are shown to be a promising technology for applications in future high luminosity experiments.
Název v anglickém jazyce
Diamond detectors for high energy physics experiments
Popis výsledku anglicky
Beam test results of the radiation tolerance study of chemical vapour deposition (CVD) diamond against different particle species and energies is presented. We also present beam test results on the independence of signal size on incident particle rate in charged particle detectors based on un-irradiated and irradiated poly-crystalline CVD diamond over a range of particle fluxes from 2 kHz/cm(2) to 10 MHz/cm(2). The pulse height of the sensors was measured with readout electronics with a peaking time of 6 ns. In addition functionality of poly-crystalline CVD diamond 3D devices was demonstrated in beam tests and 3D diamond detectors are shown to be a promising technology for applications in future high luminosity experiments.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10304 - Nuclear physics
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Instrumentation
ISSN
1748-0221
e-ISSN
1748-0221
Svazek periodika
13
Číslo periodika v rámci svazku
Jan
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
8
Strana od-do
—
Kód UT WoS článku
000423302400004
EID výsledku v databázi Scopus
2-s2.0-85041820546