ACOUSTIC DESIGN OF NOISE PROTECTION AND NOISE MAPPING FOR HEAT PUMPS IN THE COURTYARD OF A RESIDENTIAL BUILDING
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F18%3A00322674" target="_blank" >RIV/68407700:21220/18:00322674 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85058687587&origin=inward" target="_blank" >http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85058687587&origin=inward</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
ACOUSTIC DESIGN OF NOISE PROTECTION AND NOISE MAPPING FOR HEAT PUMPS IN THE COURTYARD OF A RESIDENTIAL BUILDING
Popis výsledku v původním jazyce
This paper deals with the assessment and design of acoustic protection for the heat pumps installed in the courtyard of a residential building where stricter hygiene limits on noise are valid. The paper deals with two different cases of the heat pump installation. The heat pumps are used as a combination of air mass and water (or coolant) in both cases. The heat pump system is used in both cases for cooling and heating during the day and night of the residential and non-residential building and it needs greater acoustic protection be-cause of stricter hygiene limits on noise for night operation. The installation of the units and the construction was already under implementation so there was not any chance to fundamentally change the project, therefore there was little room for acoustic design ad-justments. The goal of the paper is to compare the calculated data from simulations with the measured data in-situ.
Název v anglickém jazyce
ACOUSTIC DESIGN OF NOISE PROTECTION AND NOISE MAPPING FOR HEAT PUMPS IN THE COURTYARD OF A RESIDENTIAL BUILDING
Popis výsledku anglicky
This paper deals with the assessment and design of acoustic protection for the heat pumps installed in the courtyard of a residential building where stricter hygiene limits on noise are valid. The paper deals with two different cases of the heat pump installation. The heat pumps are used as a combination of air mass and water (or coolant) in both cases. The heat pump system is used in both cases for cooling and heating during the day and night of the residential and non-residential building and it needs greater acoustic protection be-cause of stricter hygiene limits on noise for night operation. The installation of the units and the construction was already under implementation so there was not any chance to fundamentally change the project, therefore there was little room for acoustic design ad-justments. The goal of the paper is to compare the calculated data from simulations with the measured data in-situ.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20306 - Audio engineering, reliability analysis
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 25th International Congress on Sound and Vibration
ISBN
978-83-7880-552-6
ISSN
—
e-ISSN
2329-3675
Počet stran výsledku
8
Strana od-do
—
Název nakladatele
IIAV - International Institute of Acoustics and Vibration
Místo vydání
Auburn
Místo konání akce
Hiroshima
Datum konání akce
8. 7. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—