The characterization of anodic oxide layers on selected bio-compatible titanium alloys
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F18%3A00325664" target="_blank" >RIV/68407700:21220/18:00325664 - isvavai.cz</a>
Výsledek na webu
<a href="https://ojs.cvut.cz/ojs/index.php/ap/article/view/4716" target="_blank" >https://ojs.cvut.cz/ojs/index.php/ap/article/view/4716</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.14311/AP.2018.58.0240" target="_blank" >10.14311/AP.2018.58.0240</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The characterization of anodic oxide layers on selected bio-compatible titanium alloys
Popis výsledku v původním jazyce
Oxide layers on titanium alloy surfaces have an influence on bio-compatibility and corrosion resistance. In order to improve them, properties of oxide layers are examined. The oxide layer can be prepared by different methods and under various conditions. This results in a creation of layers showing different composition, structure, properties, stability, adhesion and biocompatibility. In the presented paper, samples of three titanium alloys were used: Commercially Pure (CP) titanium grade 2, Ti6Al4V alloy and beta-titanium alloy Ti-39 wt.% Nb. Samples were anodically (1 M H2SO4 / 100V / 1 hour) oxidized. Changes in surface colouration and roughness were observed. The thickness of oxide layers was measured using a scanning electron microscope (SEM). The SEM was then used for observation of the surface topography of oxidized samples. The chemical composition of the surface layers was defined by X-ray photoelectron spectroscopy (XPS).
Název v anglickém jazyce
The characterization of anodic oxide layers on selected bio-compatible titanium alloys
Popis výsledku anglicky
Oxide layers on titanium alloy surfaces have an influence on bio-compatibility and corrosion resistance. In order to improve them, properties of oxide layers are examined. The oxide layer can be prepared by different methods and under various conditions. This results in a creation of layers showing different composition, structure, properties, stability, adhesion and biocompatibility. In the presented paper, samples of three titanium alloys were used: Commercially Pure (CP) titanium grade 2, Ti6Al4V alloy and beta-titanium alloy Ti-39 wt.% Nb. Samples were anodically (1 M H2SO4 / 100V / 1 hour) oxidized. Changes in surface colouration and roughness were observed. The thickness of oxide layers was measured using a scanning electron microscope (SEM). The SEM was then used for observation of the surface topography of oxidized samples. The chemical composition of the surface layers was defined by X-ray photoelectron spectroscopy (XPS).
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
20506 - Coating and films
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta Polytechnica
ISSN
1210-2709
e-ISSN
1805-2363
Svazek periodika
58
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
5
Strana od-do
240-244
Kód UT WoS článku
000444034700004
EID výsledku v databázi Scopus
2-s2.0-85053370697