A study of the radiation tolerance of poly-crystalline and single-crystalline CVD diamond to 800 MeV and 24 GeV protons
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F19%3A00334040" target="_blank" >RIV/68407700:21220/19:00334040 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21340/19:00334040
Výsledek na webu
<a href="https://doi.org/10.1088/1361-6463/ab37c6" target="_blank" >https://doi.org/10.1088/1361-6463/ab37c6</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1361-6463/ab37c6" target="_blank" >10.1088/1361-6463/ab37c6</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A study of the radiation tolerance of poly-crystalline and single-crystalline CVD diamond to 800 MeV and 24 GeV protons
Popis výsledku v původním jazyce
We have measured the radiation tolerance of poly-crystalline and single-crystalline diamonds grown by the chemical vapor deposition (CVD) process by measuring the charge collected before and after irradiation in a 50 mu m pitch strip detector fabricated on each diamond sample. We irradiated one group of sensors with 800 MeV protons, and a second group of sensors with 24 GeV protons, in steps, to (1.34 +/- 0.08 x 10(16)) protons cm(-2) and (1.80 +/- 0.18 x 10(16)) protons cm(-2) respectively. We observe the sum of mean drift paths for electrons and holes for both poly-crystalline CVD diamond and single-crystalline CVD diamond decreases with irradiation fluence from its initial value according to a simple damage curve characterized by a damage constant for each irradiation energy and the irradiation fluence. We find for each irradiation energy the damage constant, for poly-crystalline CVD diamond to be the same within statistical errors as the damage constant for single-crystalline CVD diamond. We find the damage constant for diamond irradiated with 24 GeV protons to be 0.62( -0.01)(+0.01) (stat) (+0.06)(-0.06) (syst) x 10(-18) cm(2) (p mu m)(-1) and the damage constant for diamond irradiated with 800 MeV protons to be 1.04 (+0.02)(-0.02) (stat) (-0.04)(-0.05) (syst) x 10(-18) cm(2) (p mu m)(-1) Moreover, we observe the FWHM/MP pulse height decreases with fluence for poly-crystalline CVD material and within statistical errors does not change with fluence for single-crystalline CVD material for both 24 GeV proton irradiation and 800 MeV proton irradiation. Finally, we have measured the uniformity of each sample as a function of fluence and observed that for poly-crystalline CVD diamond the samples become more uniform with fluence while for single-crystalline CVD diamond the uniformity does not change with fluence.
Název v anglickém jazyce
A study of the radiation tolerance of poly-crystalline and single-crystalline CVD diamond to 800 MeV and 24 GeV protons
Popis výsledku anglicky
We have measured the radiation tolerance of poly-crystalline and single-crystalline diamonds grown by the chemical vapor deposition (CVD) process by measuring the charge collected before and after irradiation in a 50 mu m pitch strip detector fabricated on each diamond sample. We irradiated one group of sensors with 800 MeV protons, and a second group of sensors with 24 GeV protons, in steps, to (1.34 +/- 0.08 x 10(16)) protons cm(-2) and (1.80 +/- 0.18 x 10(16)) protons cm(-2) respectively. We observe the sum of mean drift paths for electrons and holes for both poly-crystalline CVD diamond and single-crystalline CVD diamond decreases with irradiation fluence from its initial value according to a simple damage curve characterized by a damage constant for each irradiation energy and the irradiation fluence. We find for each irradiation energy the damage constant, for poly-crystalline CVD diamond to be the same within statistical errors as the damage constant for single-crystalline CVD diamond. We find the damage constant for diamond irradiated with 24 GeV protons to be 0.62( -0.01)(+0.01) (stat) (+0.06)(-0.06) (syst) x 10(-18) cm(2) (p mu m)(-1) and the damage constant for diamond irradiated with 800 MeV protons to be 1.04 (+0.02)(-0.02) (stat) (-0.04)(-0.05) (syst) x 10(-18) cm(2) (p mu m)(-1) Moreover, we observe the FWHM/MP pulse height decreases with fluence for poly-crystalline CVD material and within statistical errors does not change with fluence for single-crystalline CVD material for both 24 GeV proton irradiation and 800 MeV proton irradiation. Finally, we have measured the uniformity of each sample as a function of fluence and observed that for poly-crystalline CVD diamond the samples become more uniform with fluence while for single-crystalline CVD diamond the uniformity does not change with fluence.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10303 - Particles and field physics
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Physics D: Applied Physics
ISSN
0022-3727
e-ISSN
1361-6463
Svazek periodika
52
Číslo periodika v rámci svazku
46
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
16
Strana od-do
—
Kód UT WoS článku
000484121900002
EID výsledku v databázi Scopus
2-s2.0-85073120220