Pulse shape analysing system for a gridded ionization chamber
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F19%3A00336930" target="_blank" >RIV/68407700:21220/19:00336930 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21670/19:00336930
Výsledek na webu
<a href="https://doi.org/10.1088/1748-0221/14/11/T11005" target="_blank" >https://doi.org/10.1088/1748-0221/14/11/T11005</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1748-0221/14/11/T11005" target="_blank" >10.1088/1748-0221/14/11/T11005</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Pulse shape analysing system for a gridded ionization chamber
Popis výsledku v původním jazyce
Digital pulse shape analysis (dpsa) has been used with a Frisch-gridded ionization chamber to study the charged particle emission reactions induced by fast neutrons. The structure of Frisch-gridded ionization chamber and his performance were presented in more detail in ref. [1]. Here we describe experimental use of the ionization chamber combined with PXI system in detection of charged particles. The PXI system consisting of a chassis NI PXI-1031, an embedded controller NI PXI-8820 and a high-speed digitizer pixie-4 from XIA [2]. The pixie-4 is a PCI/PXI 4-channel all-digital waveform data-acquisition card featuring on-line pulse-shape analysis. Incoming signals are digitized with 14-bit 75 msps ADCs. Rise-time dpsa has been employed using data as an examples measurements of charged particles originating from reactions on <sup>6</sup>Li and <sup>10</sup>B nuclei induced by thermalized neutrons from an <sup>241</sup>Am-Be source.
Název v anglickém jazyce
Pulse shape analysing system for a gridded ionization chamber
Popis výsledku anglicky
Digital pulse shape analysis (dpsa) has been used with a Frisch-gridded ionization chamber to study the charged particle emission reactions induced by fast neutrons. The structure of Frisch-gridded ionization chamber and his performance were presented in more detail in ref. [1]. Here we describe experimental use of the ionization chamber combined with PXI system in detection of charged particles. The PXI system consisting of a chassis NI PXI-1031, an embedded controller NI PXI-8820 and a high-speed digitizer pixie-4 from XIA [2]. The pixie-4 is a PCI/PXI 4-channel all-digital waveform data-acquisition card featuring on-line pulse-shape analysis. Incoming signals are digitized with 14-bit 75 msps ADCs. Rise-time dpsa has been employed using data as an examples measurements of charged particles originating from reactions on <sup>6</sup>Li and <sup>10</sup>B nuclei induced by thermalized neutrons from an <sup>241</sup>Am-Be source.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10303 - Particles and field physics
Návaznosti výsledku
Projekt
<a href="/cs/project/EF16_013%2F0001785" target="_blank" >EF16_013/0001785: Urychlovač Van de Graaff - laditelný zdroj monoenergetických neutronů a lehkých iontů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Instrumentation
ISSN
1748-0221
e-ISSN
1748-0221
Svazek periodika
14
Číslo periodika v rámci svazku
11
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
5
Strana od-do
—
Kód UT WoS článku
000507592100003
EID výsledku v databázi Scopus
2-s2.0-85090381084