Use of durometer to determine trapezius muscle relaxation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F19%3A00337533" target="_blank" >RIV/68407700:21220/19:00337533 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Use of durometer to determine trapezius muscle relaxation
Popis výsledku v původním jazyce
Measurement of the muscle tension are normally done with specialized apparatus, a.k.a. myotonometers. These devices need specialized personnel, sophisticated electric drive, feedback control and mostly static construction. Hence the high purchase and operating costs of these devices. For these reasons, the requirement for our device arose. The basic requirements are the manual size of the apparatus and the possibility of measuring various muscles all over the body. The apparatus works on the principle of indentor injection into the tissue. The measured quantity is the resistance that the tissue puts. The maximum indentation depth is adjustable and constant during all partial measurements. Another use of apparatus is to objectify the Palpation Test. The evaluation of this test is highly subjective and depends on the experience of the implementing specialist. With help of this apparatus it is possible to visualize result while facilitating the transfer of experience among clinical experts. The apparatus is designed to by attached to the respective muscles and the indentor is manually pushed into the muscle. A compression spring is used to reverse movement. The threaded rod is used as a beam between the measuring sensor and the handle. This makes it possible to use nuts as an adjustable depth of indentation. The measuring sensor is one-Axis pressure gauge from Kisler.
Název v anglickém jazyce
Use of durometer to determine trapezius muscle relaxation
Popis výsledku anglicky
Measurement of the muscle tension are normally done with specialized apparatus, a.k.a. myotonometers. These devices need specialized personnel, sophisticated electric drive, feedback control and mostly static construction. Hence the high purchase and operating costs of these devices. For these reasons, the requirement for our device arose. The basic requirements are the manual size of the apparatus and the possibility of measuring various muscles all over the body. The apparatus works on the principle of indentor injection into the tissue. The measured quantity is the resistance that the tissue puts. The maximum indentation depth is adjustable and constant during all partial measurements. Another use of apparatus is to objectify the Palpation Test. The evaluation of this test is highly subjective and depends on the experience of the implementing specialist. With help of this apparatus it is possible to visualize result while facilitating the transfer of experience among clinical experts. The apparatus is designed to by attached to the respective muscles and the indentor is manually pushed into the muscle. A compression spring is used to reverse movement. The threaded rod is used as a beam between the measuring sensor and the handle. This makes it possible to use nuts as an adjustable depth of indentation. The measuring sensor is one-Axis pressure gauge from Kisler.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20301 - Mechanical engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
EAN 2019 57th conference on experimental stress analysis CONFERENCE PROCEEDINGS
ISBN
9788021457669
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
517-520
Název nakladatele
Česká společnost pro mechaniku
Místo vydání
Praha
Místo konání akce
Luhačovice
Datum konání akce
3. 6. 2019
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000568113800082