Popis výsledku v původním jazyce
The paper describes the use of a recently published method of relay feedback identification (called the shifting method) for estimation of the second order time delayed system model. An algorithm is designed for estimation of model parameters from two points of the frequency characteristics of the identified system. Both points are obtained from a single relay feedback test without any assumption about the model transfer function. The relay shifting method used here was modified by using an integrator in the feedback loop or an added time delay in closed loop. It allows to estimate points of frequency characteristics in positions more suitable for model fitting than the original shifting method approach. This modification enables a better estimate of the static gain even under constant load disturbance. The identified process model was used to calculate the PID controller parameters. The proposed solution is demonstrated on simulated and real examples.
Název v anglickém jazyce
The use of relay shifting method of process identification for auto tuning of PID controller
Popis výsledku anglicky
The paper describes the use of a recently published method of relay feedback identification (called the shifting method) for estimation of the second order time delayed system model. An algorithm is designed for estimation of model parameters from two points of the frequency characteristics of the identified system. Both points are obtained from a single relay feedback test without any assumption about the model transfer function. The relay shifting method used here was modified by using an integrator in the feedback loop or an added time delay in closed loop. It allows to estimate points of frequency characteristics in positions more suitable for model fitting than the original shifting method approach. This modification enables a better estimate of the static gain even under constant load disturbance. The identified process model was used to calculate the PID controller parameters. The proposed solution is demonstrated on simulated and real examples.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
20205 - Automation and control systems
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal of Circuits, Systems and Signal Processing
ISSN
1998-4464
e-ISSN
1998-4464
Svazek periodika
13
Číslo periodika v rámci svazku
Oct
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
6
Strana od-do
721-726
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85086637300