The Leakage of Steam Mass Flow Rate through the Gland Seals – Influence on Turbine Produced Power
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F20%3A00345306" target="_blank" >RIV/68407700:21220/20:00345306 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.18048/2020.58.03" target="_blank" >https://doi.org/10.18048/2020.58.03</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.18048/2020.58.03" target="_blank" >10.18048/2020.58.03</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Leakage of Steam Mass Flow Rate through the Gland Seals – Influence on Turbine Produced Power
Popis výsledku v původním jazyce
In this paper is presented an analysis of gland seals operation and their influence on the performance of low power steam turbine with two cylinders and steam reheating, which can be used in marine applications. Performed analysis presents a comparison of steam turbine main operating parameters when gland seals operation is neglected (as usual in the most of the literature) and when steam mass flow rates leaked through all gland seals are taken into consideration. Steam mass flow rate leakage through all gland seals reduces produced power of the whole turbine and both of its cylinders. Operation of gland seal mounted at the inlet in the first cylinder of any steam turbine (cylinder which operates with the steam of the highest pressure) has the most notable influence on the reduction of the whole turbine produced power. Gland seal mounted at the outlet of the last turbine cylinder (cylinder which operates with the steam of the lowest pressure) did not have any influence on the reduction of steam turbine produced power. In any detail analysis of a steam turbine (especially the complex turbine with multiple cylinders), gland seals operation should be considered due to their notable influence on the turbine performance.
Název v anglickém jazyce
The Leakage of Steam Mass Flow Rate through the Gland Seals – Influence on Turbine Produced Power
Popis výsledku anglicky
In this paper is presented an analysis of gland seals operation and their influence on the performance of low power steam turbine with two cylinders and steam reheating, which can be used in marine applications. Performed analysis presents a comparison of steam turbine main operating parameters when gland seals operation is neglected (as usual in the most of the literature) and when steam mass flow rates leaked through all gland seals are taken into consideration. Steam mass flow rate leakage through all gland seals reduces produced power of the whole turbine and both of its cylinders. Operation of gland seal mounted at the inlet in the first cylinder of any steam turbine (cylinder which operates with the steam of the highest pressure) has the most notable influence on the reduction of the whole turbine produced power. Gland seal mounted at the outlet of the last turbine cylinder (cylinder which operates with the steam of the lowest pressure) did not have any influence on the reduction of steam turbine produced power. In any detail analysis of a steam turbine (especially the complex turbine with multiple cylinders), gland seals operation should be considered due to their notable influence on the turbine performance.
Klasifikace
Druh
J<sub>ost</sub> - Ostatní články v recenzovaných periodicích
CEP obor
—
OECD FORD obor
20301 - Mechanical engineering
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Maritime & Transportation Sciences
ISSN
0554-6397
e-ISSN
—
Svazek periodika
58
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
HR - Chorvatská republika
Počet stran výsledku
18
Strana od-do
39-56
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—