Reconfiguring TRNSYS Type 158 for direct fired water heaters: Model verification and simulation performance analysis
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F24%3A00376506" target="_blank" >RIV/68407700:21220/24:00376506 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21720/24:00376506
Výsledek na webu
<a href="https://doi.org/10.1016/j.enbuild.2024.114692" target="_blank" >https://doi.org/10.1016/j.enbuild.2024.114692</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.enbuild.2024.114692" target="_blank" >10.1016/j.enbuild.2024.114692</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Reconfiguring TRNSYS Type 158 for direct fired water heaters: Model verification and simulation performance analysis
Popis výsledku v původním jazyce
This article presents novel insights into direct-fired water heaters with a storage tank, making a significant contribution to the scientific community. The paper has two main objectives. Firstly, it examines the possibility of reconfiguring the standard mathematical model Type 158, originally designed for indirect heated storage tanks in the TRNSYS database, for use with direct heated storage tanks. The study demonstrates that the reconfigured Type 158 model produces deviations in water temperature during charging, ranging from -2.3 % to + 0.80 % compared to the manufacturer’s technical specifications. A detailed procedure for reconfiguring this model is provided, filling a gap in existing literature. Secondly, the paper uses the reconfigured model to analyse the usage of direct water heaters for dual purposes: space heating and hot water supply. System simulations in three realistic installation scenarios—single-family house, hand car wash, and apartment building—validate the findings. The first scenario evaluates the heater at very low load, the second assesses its performance with low space heating and high hot water demand, and the third highlights potential shortcomings in buildings with high space heating and hot water demand. These simulations provide valuable data on the heater’s ability to meet energy supply needs in different contexts, demonstrating its practicality and effectiveness.
Název v anglickém jazyce
Reconfiguring TRNSYS Type 158 for direct fired water heaters: Model verification and simulation performance analysis
Popis výsledku anglicky
This article presents novel insights into direct-fired water heaters with a storage tank, making a significant contribution to the scientific community. The paper has two main objectives. Firstly, it examines the possibility of reconfiguring the standard mathematical model Type 158, originally designed for indirect heated storage tanks in the TRNSYS database, for use with direct heated storage tanks. The study demonstrates that the reconfigured Type 158 model produces deviations in water temperature during charging, ranging from -2.3 % to + 0.80 % compared to the manufacturer’s technical specifications. A detailed procedure for reconfiguring this model is provided, filling a gap in existing literature. Secondly, the paper uses the reconfigured model to analyse the usage of direct water heaters for dual purposes: space heating and hot water supply. System simulations in three realistic installation scenarios—single-family house, hand car wash, and apartment building—validate the findings. The first scenario evaluates the heater at very low load, the second assesses its performance with low space heating and high hot water demand, and the third highlights potential shortcomings in buildings with high space heating and hot water demand. These simulations provide valuable data on the heater’s ability to meet energy supply needs in different contexts, demonstrating its practicality and effectiveness.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Energy and Buildings
ISSN
0378-7788
e-ISSN
1872-6178
Svazek periodika
322
Číslo periodika v rámci svazku
-
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
18
Strana od-do
—
Kód UT WoS článku
001301755200001
EID výsledku v databázi Scopus
2-s2.0-85201908535