Anisotropic Magnetoresistor Cross Axis Effect Measurement
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F03%3A03089813" target="_blank" >RIV/68407700:21230/03:03089813 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Anisotropic Magnetoresistor Cross Axis Effect Measurement
Popis výsledku v původním jazyce
Anizotropic magnetoresistive (AMR) sensors show unwanted sensitivity to the external field applied in the direction perpendicular to their axis of sensitivity. This cross axis effect can cause an error of the magnetic field amplitude reading when the applied field is not parallel to the direction of the axis of sensitivity. This paper presents a simple method, how to measure the cross axis effect and also results of the Honeywell HMC 1002 sensor measurement. The theory of AMR sensors is discussed in [1]. The AMRs are presently being used for sensing small fields such as the Earth's field (~ 48 uT amplitude, ~ 18 uT horizontal component - central Europe) for navigation purposes. Elimination of all possible sources of errors such as cross axis effect error is then necessary for accurate measurement and direction determining.
Název v anglickém jazyce
Anisotropic Magnetoresistor Cross Axis Effect Measurement
Popis výsledku anglicky
Anizotropic magnetoresistive (AMR) sensors show unwanted sensitivity to the external field applied in the direction perpendicular to their axis of sensitivity. This cross axis effect can cause an error of the magnetic field amplitude reading when the applied field is not parallel to the direction of the axis of sensitivity. This paper presents a simple method, how to measure the cross axis effect and also results of the Honeywell HMC 1002 sensor measurement. The theory of AMR sensors is discussed in [1]. The AMRs are presently being used for sensing small fields such as the Earth's field (~ 48 uT amplitude, ~ 18 uT horizontal component - central Europe) for navigation purposes. Elimination of all possible sources of errors such as cross axis effect error is then necessary for accurate measurement and direction determining.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2003
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Poster 2003
ISBN
—
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
"EI-17"-"EI-17"
Název nakladatele
ČVUT, Fakulta elektrotechnická
Místo vydání
Praha
Místo konání akce
Prague
Datum konání akce
22. 5. 2003
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—