Není k dispozici
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F04%3A03096066" target="_blank" >RIV/68407700:21230/04:03096066 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Effectivity of Tracheal Gas Insufflation on Artificial Lung Ventilation
Popis výsledku v původním jazyce
The aim of this work was to find out the effect of tracheal gas insufflation during conventional and high frequency artificial lung ventilation upon arterial blood gases. The complicated lung structure does not allow an exact modelling according to the anatomical lung structure. Therefore, the respiration system is modelled as an axial symmetrical straight pipe with a growing radius. A base of the model is convention-diffusion equation, which is solved by numerical simulation. After that, the TGI catheter was added into the model for description of tracheal gas insufflation effect. The TGI catheter was modelled as an additional source of ventilation gas mixture. The outputs of the final model were compared not only with an animal experiment but also with another model derived from the electro-acoustic analogy. The acquired results are useful and directly applicable in TGI effect investigation and will, hopefully, contribute to the fast TGI introduction into the clinical practice.
Název v anglickém jazyce
Effectivity of Tracheal Gas Insufflation on Artificial Lung Ventilation
Popis výsledku anglicky
The aim of this work was to find out the effect of tracheal gas insufflation during conventional and high frequency artificial lung ventilation upon arterial blood gases. The complicated lung structure does not allow an exact modelling according to the anatomical lung structure. Therefore, the respiration system is modelled as an axial symmetrical straight pipe with a growing radius. A base of the model is convention-diffusion equation, which is solved by numerical simulation. After that, the TGI catheter was added into the model for description of tracheal gas insufflation effect. The TGI catheter was modelled as an additional source of ventilation gas mixture. The outputs of the final model were compared not only with an animal experiment but also with another model derived from the electro-acoustic analogy. The acquired results are useful and directly applicable in TGI effect investigation and will, hopefully, contribute to the fast TGI introduction into the clinical practice.
Klasifikace
Druh
A - Audiovizuální tvorba
CEP obor
FS - Lékařská zařízení, přístroje a vybavení
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
ISBN
0-88986-379-2
Místo vydání
Zürich
Název nakladatele resp. objednatele
—
Verze
—
Identifikační číslo nosiče
neuvedeno