Automatic QT Interval Measurement Using Rule-Based Gradient Method
Popis výsledku v původním jazyce
In this work, we address the problem of fully automated QT-interval measurement. The method is based on detecting the Q and T points via gradient method accordingly to the beat morphology. Development and validation of the algorithm have been done usingthe PTB Diagnostic ECG Database prepared for Computers in Cardiology Challenge 2006. RR analysis is used for selection of the beat on which QT interval is measured. The beginning of the Q-wave is detected on all 12-leads. Considering Toff detection, morphology of repolarization phase of the beat is determined. Based on the morphology, rules are applied to particular gradients of repolarization phase to determine the T-wave end. Additional rules were applied to omit signals with high probability of the wrong QT interval measurement. With our method we have reached a score of 35.58ms.
Název v anglickém jazyce
Automatic QT Interval Measurement Using Rule-Based Gradient Method
Popis výsledku anglicky
In this work, we address the problem of fully automated QT-interval measurement. The method is based on detecting the Q and T points via gradient method accordingly to the beat morphology. Development and validation of the algorithm have been done usingthe PTB Diagnostic ECG Database prepared for Computers in Cardiology Challenge 2006. RR analysis is used for selection of the beat on which QT interval is measured. The beginning of the Q-wave is detected on all 12-leads. Considering Toff detection, morphology of repolarization phase of the beat is determined. Based on the morphology, rules are applied to particular gradients of repolarization phase to determine the T-wave end. Additional rules were applied to omit signals with high probability of the wrong QT interval measurement. With our method we have reached a score of 35.58ms.
Klasifikace
Druh
A - Audiovizuální tvorba
CEP obor
JC - Počítačový hardware a software
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/1ET201210527" target="_blank" >1ET201210527: Znalostní podpora diagnostiky a predikce v kardiologii</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
ISBN
—
Místo vydání
Piscataway
Název nakladatele resp. objednatele
—
Verze
—
Identifikační číslo nosiče
neuvedeno