Structure and Tribology of Biocompatible Ti-C:H Coatings
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F07%3A00142349" target="_blank" >RIV/68407700:21230/07:00142349 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21220/07:00142349 RIV/68407700:21260/07:00142349
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Structure and Tribology of Biocompatible Ti-C:H Coatings
Popis výsledku v původním jazyce
Ti-C:H coatings with different carbon content for biomedical applications were deposited by PECVD. Ti was varied by magnetron sputtering a Ti-target with different power in a dc discharge regime having Ar in the atmosphere. The tribological properties were studied using a pin-on-disc CSM Tribometer in order to ensure stable tribological properties of the whole Ti-C:H/DLC system for any case of top layer failure. The sliding tests were carried out at room temperature in room environment with relative airhumidity 40+-5%, in 0.9% NaCl water solution (physiological solution, PS) and in 10% fetal bovine serum (FBS) dissolved in Ringer's saline solution using 440C steel balls with a diameter of 8 mm. The Ti-rich coatings exhibited poor wear resistance, while the best tribological properties were achieved for TiC/a-C:H coatings deposited with the highest C2H2 flows.
Název v anglickém jazyce
Structure and Tribology of Biocompatible Ti-C:H Coatings
Popis výsledku anglicky
Ti-C:H coatings with different carbon content for biomedical applications were deposited by PECVD. Ti was varied by magnetron sputtering a Ti-target with different power in a dc discharge regime having Ar in the atmosphere. The tribological properties were studied using a pin-on-disc CSM Tribometer in order to ensure stable tribological properties of the whole Ti-C:H/DLC system for any case of top layer failure. The sliding tests were carried out at room temperature in room environment with relative airhumidity 40+-5%, in 0.9% NaCl water solution (physiological solution, PS) and in 10% fetal bovine serum (FBS) dissolved in Ringer's saline solution using 440C steel balls with a diameter of 8 mm. The Ti-rich coatings exhibited poor wear resistance, while the best tribological properties were achieved for TiC/a-C:H coatings deposited with the highest C2H2 flows.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
JI - Kompositní materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů