Měření spontánní ultra slabé emise fotonu z lidského těla: Spontánní emise fotonu se počas dne mění
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F07%3A03131189" target="_blank" >RIV/68407700:21230/07:03131189 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Measurement of Spontaneous Ultra-Weak Photon Emission Froma Human Body: Spontaneous Ultra-Weak Photon Emission Varies Diurnally
Popis výsledku v původním jazyce
Spontaneous ultra-weak photon emission in the visible range was measured on palm and dorsal side of left and right hand by means of a low noise photomultiplier system. To study the dynamics of this photon emission in a 24h period photon emission was recorded in 2h intervals in 5 experiments, utilizing strict protocols for dark adaptation and recording of subjects. Mean photon emission over the 24h period differed both between subjects and hand locations. To detect a pattern in the fluctuations the meanvalue for each location of each subject in each experiment was utilized to calculate fluctuations during the course of 24h for each anatomical location. The fluctuations in photon emission in the course of 24h were more at dorsal sides than palm sides. Photon emission at the left dorsal location was high at night, while the right dorsal side emitted most during the day. Daily rhytm in photon emission can be recorded from both the dorsal and palm sides of the hands.
Název v anglickém jazyce
Measurement of Spontaneous Ultra-Weak Photon Emission Froma Human Body: Spontaneous Ultra-Weak Photon Emission Varies Diurnally
Popis výsledku anglicky
Spontaneous ultra-weak photon emission in the visible range was measured on palm and dorsal side of left and right hand by means of a low noise photomultiplier system. To study the dynamics of this photon emission in a 24h period photon emission was recorded in 2h intervals in 5 experiments, utilizing strict protocols for dark adaptation and recording of subjects. Mean photon emission over the 24h period differed both between subjects and hand locations. To detect a pattern in the fluctuations the meanvalue for each location of each subject in each experiment was utilized to calculate fluctuations during the course of 24h for each anatomical location. The fluctuations in photon emission in the course of 24h were more at dorsal sides than palm sides. Photon emission at the left dorsal location was high at night, while the right dorsal side emitted most during the day. Daily rhytm in photon emission can be recorded from both the dorsal and palm sides of the hands.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings Measurement 2007
ISBN
978-80-969672-0-9
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
421-424
Název nakladatele
Institute of Measurement Science of the SAS
Místo vydání
Bratislava
Místo konání akce
Smolenice
Datum konání akce
20. 5. 2007
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—